push button

panel tabs

side panel

Removable Side Panel

SIDE PANEL OPERATION

For easy cleaning and access to the side / 
underside of the recliner, Lumex Clinical 
Care Recliners feature easy-to-remove 
side panels.

To Remove Side Panel

Depress the two push buttons located on 
the lower sides of frame. Pull side panel 
gently away and down from frame. There 
are tabs on the frame underneath the 
armrest that hold the side panel in place.

To Install Side Panel

Insert side panel into recliner frame by locating the tabs underneath the armrest. Make sure side 
panel is properly aligned and that the top edge is behind the locking tabs. Press side panel into 
frame sides. Make sure that both push buttons are protruding into side panel to ensure side panel 
is locked into place.

RECLINER OPERATION

The Lumex Series FR577RG Recliners feature three positions for patient comfort. The fourth 
position is a Trendelenburg (or shock) position that must be activated by a caregiver. The 
Trendelenburg Position CANNOT be activated by a patient while in the recliner. In addition, the 
Series FR577RG features a back that can be repositioned via the Adjustment Lever located on the 
Push Handle on the back of the recliner.

First Position (Upright Position)

The first position is the 

Upright Position

. This position is ideal for 

patient transport and can be used to initiate patient treatment / 
therapy.

Second Position (First Recline Position)

The second position is the 

First Recline Position

 and is also known as 

the “TV” position. This position is ideal for patient treatment, rest and 
reading.

To Achieve Second Position / First Recline Position:

•  By the Patient: Place hands on armrest and push body against 

recliner back to recline yourself to desired position. To bring 
yourself up, place hands on armrest and pull yourself up while 
leaning your body forward, away from the recliner back, while at the 
same time pushing down evenly on the footrest with your legs.

•  Reclining by Attendant: Standing on either side of the recliner, grasp 

the armrest with one hand and push handle with the other hand. Push back on push handle to 
recline. To return, grasp push handle and pull forward to raise the recliner back.

s

  NOTICE: DO NOT use the footrest by itself to return the recliner to an upright position 

from any recline position. Doing so may damage the recliner mechanism. Follow the 

instructions above to operate the recliner.

Upright Position

First Recline Position

(TV Position)

Second Recline Position

(Full Recline Position)

Trendelenburg Position

(Shock Position)

Upright Position

First Recline Position

(TV Position)

Second Recline Position

(Full Recline Position)

Trendelenburg Position

(Shock Position)

Summary of Contents for LUMEX FR577RGH

Page 1: ...Care Recliner Series FR577RGH Clinical Care Recliner with Heat and Massage Series FR577RGHO Clinical Care Recliner with Heat Only Assembly and Operating Instructions SAVE THIS MANUAL FOR FUTURE USE LX...

Page 2: ...TION ALSO KNOWN AS SHOCK POSITION 10 GAS SPRING TROUBLESHOOTING GUIDE 11 ADJUSTING CABLE TENSION 11 RECLINERS WITH HEAT AND MASSAGE OR HEAT ONLY FEATURE 12 INSTALLATION AND OPERATING GUIDE 12 DESCRIPT...

Page 3: ...e the following special statements used throughout this manual and their significance WARNING Indicates a potential hazard situation or unsafe practice that if not avoided could result in death or ser...

Page 4: ...ardous condition which may result in serious injury and will void the warranty WARNING This product can expose you to chemicals including Di 2 ethylhexyl phthalate DEHP which is known to the State of...

Page 5: ...gas spring actuating lever total locking caster total of 3 on recliner black locking tab rear directional swivel locking caster right rear leg only green locking tab Clinical Care Recliner Series FR5...

Page 6: ...ace 5 Lift the upholstered back from the sides and place it horizontally with the upright back tubes resting on the recliner frame 6 Align the holes on the upright back tubes of the upholstered back w...

Page 7: ...r clevis pins through the U bracket and hinge with the other hand 9 Secure the clevis pin by placing the ring cotter pin through the hole in the clevis pin as shown at right 10 Replace side panels Ins...

Page 8: ...ectional swivel caster The fourth caster located on the right rear position of the recliner is a directional swivel locking caster only Identified by a green actuator tab the directional lock caster w...

Page 9: ...back of the recliner First Position Upright Position The first position is the Upright Position This position is ideal for patient transport and can be used to initiate patient treatment therapy Seco...

Page 10: ...position the headrest section from the recliner front pull forward on the upper section of the back to increase the angle of the headrest section To return headrest to normal position push headrest se...

Page 11: ...ack Remove the gas spring from the recliner by disassembling the two ring cotter pins and the two clevis pins that secure the gas spring to the back frame 2 Lower the back until it rests on the stop b...

Page 12: ...Unit offers three levels of seat and back heat as well as a gentle or firm massage function for just the lower back or both lower and upper back the Heat Only Unit offers three levels of seat and back...

Page 13: ...nly cable connections are disconnected Info Model FR577RGH Heat and Massage requires two connections one for the control box the following step 4 and the other for the massage motor the following step...

Page 14: ...ng tab snaps into place 5 For Heat and Massage Functions only Locate the black plastic corrugated tube at the lower back of the Recliner 6 For Heat and Massage Functions only Pull on the red wires com...

Page 15: ...0200RevA20 SEE OPERATING MANUAL FOR COMPLETE INSTRUCTIONS HIGH HEAT PRESS 1 TIME MEDIUM HEAT PRESS 2 TIMES LOW HEAT PRESS 3 TIMES 3 The Heat and Massage Pendant Selector Switch Faceplate shown at abov...

Page 16: ...The Heat Function Settings are as follows a Press selector switch for Setting 1 High Heat 104 F 40 C brightest LED b Press selector switch AGAIN for Setting 2 Medium Heat 101 F 38 6 C bright LED c Pr...

Page 17: ...ts f Are all cable connections to the control module in place Are the connectors fully engaged g Are any of the connectors damaged h Are the wires within the connectors attached to the pins Each wire...

Page 18: ...e 1 part isopropyl alcohol to 1 part water Info Using alcohol on a regular basis can affect the properties of the product Once a month you can use a soft bristle brush for a deeper cleaning Info Light...

Page 19: ...ning and maintaining noncritical medical equipment In the absence of a manufacturer s cleaning instructions follow certain procedures Clean noncritical medical equipment surfaces with a detergent disi...

Page 20: ...ired by facility policy or after cleaning up large spills of blood or other body substances Clean mops and cloths after use and allow to dry before reuse or use single use disposable mop heads and clo...

Page 21: ...FRAGILE HANDLE WITH CARE CE MARK CAUTION EC REP EUROPEAN AUTHORIZED REPRESENTATIVE UDI UNIQUE DEVICE IDENTIFIER GENERAL WARNING SIGN KEEP DRY ELECTRICAL AND ELECTRONIC EQUIPMENT CONSULT INSTRUCTIONS...

Page 22: ...required in the official manual for the applicable product 3 Products considered to be of a non durable nature including but not limited to filters fuses gaskets lubricants and charts 4 Accessories or...

Page 23: ...troubleshooting guide 17 I Important safety precautions 3 Info statement significance 3 Intended use 3 Introduction 3 L Limited warranty 22 N NOTICE statement significance 3 O Operation 8 P Product de...

Page 24: ...field com 2012 GF Health Products Inc All Rights Reserved Lumex is a trademark of GF Health Products Inc Tente is a trademark of TENTE GmbH Co FED REP GERMANY GF Health Products Inc is an ISO 13485 20...

Reviews: