13
5. To exit menu and return back to weighing mode, press the key.
UF-5 Function HOLD
(keep displaying the weight on the screen during several
seconds after having removed the weight from the scale)
Modes:
- HOLD 0 : HOLD Function off.
- HOLD 1 : Animal Hold function.
- PCtXXX: To set the range from 001~100 of the animal hold
- timEXX: To set 1 2 4 8 16 32 64 times within the hold range (for HOLD 1 only)
Factory default: HOLD 0
1. Press the to setup the HOLD function.
2. Use the ▲ key to select the desired mode.
3. Press the key to confirm.
4. To continue with other setups use the ► key.
5. To exit menu and return back to weighing mode, press the key.
UF-5 RS-232 Output
232 0
RS-232 disable
232 1
Stable Output – Format 1
232 2
Stream Output – Format 1
232 3
Manual Output – Format 1
232 4
Stable Output – Format 2
232 5
Stream Output – Format 2
232 6
Manual Output – Format 2
RS232 Baud rate:
b 1200
Baud rate 1200
b 2400
Baud rate 2400
b 4800
Baud rate 4800
b 9600
Baud rate 9600
b 19200
Baud rate 19200
b 38400
Baud rate 38400
Communication Protocol:
UART signal of EIA-RS232 C
Format:
1. Serial output: 1200/2400/4800/9600/19200/38400 BPS
2. Data Bits: 8 bits
3. Parity Bits: None
4. Stop Bits: 1 bit