28
Troubleshooting and Error message
Error
Message
Problem
Solution
ERR0
Exceed the zero range
The item on the pan
should be within 2﹪ of
full load.
ERR1
Model setting error.
Resolution should be
within 300-300000
Adjust or reset the
capacity first then adjust
resolution
ERR2
Initial zero point exceeds
30﹪ of full load
1.Remove the obstacle
article under the pan
2.Replace the load cell or
contact the maintenance
department.
ERR3
Exceed the A/D resolution
range
1. Replace A/D
2..Replace the load cell or
contact the maintenance
department.
ERR4
EEPROM Chksum failure
Re-weld EEPROM or
contact the maintenance
department.
ERR5
Overload condition
Remove the overload item
ERR6
Exceeds the display range
----------------------------
ERR7
Accumulated number of
weighments exceeds the
display range
Delete the exceeding
weights
ERR8
Weight limit value is higher
than the full load value
Reset the weight limit value.
ERR9
Exceed tare or pre-tare
range
0
<
Tare value
≤
full load