Temperature setting

 

 
Set the desired cabinet temperature in the following manner: 
 
It is important to make sure first that the keyboard is not locked. See how in the section 
below on keyboard locking. 
 

Press the 

 key. The compressor lamp 

 

blinks, and the current cabinet 

temperature setting is shown in the display. This indicates that the current temperature 
setting can be changed now in the following manner: 
 

Press 

 or 

 to raise or lower, respectively, the temperature setting to the 

desired level. 
 

Once the desired cabinet temperature has been set, press the 

 

 key again to save 

the new value. The compressor lamp 

 will go out, unless the compressor is running. 

 
Alternatively, by not touching the keys for a minimum of 15 seconds, the controls will switch 
back to the normal temperature display, and the value that has been set will be saved 
automatically. 
 
In the event of an interruption to the power supply, the controls will remember the 
temperature setting, and the product will start up again when the power comes back. 
 
 

Keyboard lock

 

 
The keyboard is automatically locked when it has not been used/operated for 30 seconds. 
This secures the product against unauthorised/inadvertent changes to the settings or 
switching off of the controls. 
 
To unlock the keyboard: 
 

Briefly press 

. If the display subsequently shows 

Loc 

then the controls are locked. To 

unlock the controls, press any key for approx. 3 seconds, until the display shows 

UnL

. The 

display is now unlocked and new settings can be entered. 

 

 

 

Summary of Contents for Eco Euro KG 60

Page 1: ...765041996 Rev 001 1 Operating and servicemanual Eco Midi KG FG 60 82...

Page 2: ...g the product 3 Temperature setting 4 Keyboard lock 4 Alarms 5 Error codes on the display 6 Defrosting 7 Setting the configuration parameters 8 Manufacturer s settings 9 Working setpoint and configura...

Page 3: ...this is indicated by a small control lamp which is the only one lit in the lower right corner of the display To switch the product on press for approx 3 seconds During start up the control lamp will b...

Page 4: ...mpressor is running Alternatively by not touching the keys for a minimum of 15 seconds the controls will switch back to the normal temperature display and the value that has been set will be saved aut...

Page 5: ...is shown in the display if the condenser temperature has been too high Clean the condenser filter in front of the condenser Refer to the placement of the filter in Fig 3 CSd Compressor shut off This...

Page 6: ...Control lamp for defrosting Lit continuously during defrosting Blinks while draining after completed defrosting Control lamp for evaporator fan Lit continuously when the evaporator fan is in operatio...

Page 7: ...ng is automatically performed 4 times every 24 hours by a defrost heating element Manual defrosting If the cabinet is operating under severe load frequent door opening and frequent replenishment manua...

Page 8: ...765041996 Rev 001 8 Setting the configuration parameters...

Page 9: ...765041996 Rev 001 9 Manufacturer s settings...

Page 10: ...t air temperature 4 if P4 0 1 o 2 if P4 3 inlet air temperature P7 0 100 50 50 50 50 50 inflowing air temperature percentage for the calculation of the CPT temperature P8 0 250 0 1 s S 100 100 100 100...

Page 11: ...d16 0 evaporator fan activity will depend on F2 parameter if d16 0 the evaporator fan shall remain off d8 0 3 0 0 0 0 0 defrost activation methods 0 AT INTERVALS FOR TIME defrost will be activated on...

Page 12: ...aporator fan operation when the compressor is turned off see also F7 only if F0 2 PARAM MIN MAX U M DEF GRAM FG HAV GRAM KG HAV GRAM FG FAV GRAM KG FAV DIGITAL INPUTS i0 0 5 5 2 2 2 2 effect caused by...

Page 13: ...w consumption function is activated 0 the mode shall never be aactivated PARAM MIN MAX U M DEF GRAM FG HAV GRAM KG HAV GRAM FG FAV GRAM KG FAV VARIOUS key activation POF 0 1 1 1 1 1 1 1 YES PAS 99 999...

Page 14: ...condenser temperature falls below the value set with parameter F11 provided that the compressor is switched off 22 the compressor is switched off 10 s after the activation of the input if the input i...

Page 15: ...765041996 Rev 001 15 Wiring diagram...

Reviews: