Error codes on the display
Pr1
If Pr1 is shown in the display, it means that there is an error on the
temperature sensor in the product, and service assistance should be
summoned.
The product will in the meantime attempt to maintain the set temperature.
Pr2
If the display is showing Pr2, there is an error with the evaporator sensor. The
sensor should be replaced as soon as possible. Summon service assistance.
Pr3
If Pr3 is shown in the display, it means that there is an error with the
temperature sensor in the condenser, and service assistance should be
summoned.
The product will in the meantime attempt to maintain the set temperature.
Control lamps:
The display contains the following control lamps:
Control lamp for compressor. Lit when the compressor is in operation. Blinks while
the temperature is being set, or if the compressor start has been delayed
(compressor protection).
Control lamp for defrosting. Lit continuously during defrosting. Blinks while
draining after completed defrosting.
Control lamp for evaporator fan. Lit continuously when the evaporator fan is in
operation. Blinks during delay of fan operation.
Control lamp for operation of cabinet heating elements. Lit continuously when
cabinet heating elements are in operation (Frame, glass and drainage heating
elements). This is only for freezers with glass doors (FG models).
Control lamp for compressor operating time. When this control lamp is lit, it means
that the compressor has been running for so many hours that it is time to clean the
condenser's filter, which is located immediately in front of the condenser. (Refer to
the placement of the filter in Fig. 3). When the filter has been cleaned and
remounted, the counter that shows the interval must be reset.
This control lamp is the only one in lit in the display when the product is
functioning in the state termed low consumption. To see further function indicators
and the temperature in the display, it is necessary to press one of the buttons on