22
BLOWER REMOVAL
This furnace has a blower sealing system, which is designed to be tight and rattle free. Refer
to the instructions and pictures below.
1) Shut off oil and power to furnace.
2) Open blower compartment.
3) For KLF furnace only, remove air filter.
4) Disconnect the wiring to the blower motor.
5) Remove the four (4) wing nuts securing the blower side to the base panel bracket.
KLR
KLF
6) Slide the blower toward you and then lift the blower straight up. Shift the blower out of the
furnace.
KLR
KLF
Put back the blower assembly using the reverse procedure. Ensure wiring and ground wires
are correctly reconnected.
AIR FILTERS
To maintain furnace performance and safety, replace dirty filters at least once every heating
season or as required. Use new approved disposable filters of the same size and type. Dirty,
clogged or wrong sized filters will impair the furnace performance and may cause the furnace
to shut down or overheat.
Wing Nuts
Wing Nuts