3
2.0 PRODUCT INFORMATION
CLEARANCE (minimum) TO COMBUSTIBLES
Top of Supply Plenum
1”
(25 mm)
Front (Maintenance)
24”
(610 mm)
Rear (Maintenance)
24”
(610 mm)
Side – Non-Access
1”
(25 mm)
Side – Access maintenance
24”
(610 mm)
Flue Pipe
9”
(229 mm)
Floor (Can be installed directly on combustible or non-combustible)
DRAFT PRESSURE
Breech draft pressure
-0.01” wc minimum
AIR/BLOWER DATA
Maximum external static pressure
0.5” wc
Maximum cooling unit capacity
3.0 tons... KLR-100
5.0 tons… KLR-200
5.0 tons… KLF-200
Maximum air temperature rise
See pages 14 (KLR), 15(KLF) and 34
High Limit temperature
185°F
Thermostat anticipator
See thermostat instructions
MOTOR/BLOWER
KLR-100: 1/2 hp 4 Speed / G10-8 DD or 1/2 hp ECM / G10-8
KLR-200: 3/4 hp 4 Speed / GT12-10DD or 3/4 hp ECM / GT12-10
KLF-200: 3/4 hp 4 Speed / GT12-10DD or 3/4 hp ECM / GT12-10
1/2 hp ECM /GT12-10 with a firing rate of 0.75 USGPH
FAN/HIGH LIMIT CONTROL
Honeywell ST9103A1028 Fan Center & Thermo-Disk (7” stem)
THERMOSTAT
Any wall thermostat
FUEL
Not heavier than No. 2 furnace oil.
ELECTRICAL – 120 Volts, 60 Hz
Canada
Less than 12 amps.
USA
13.3 amps, circuit protection 20 amps.
Summary of Contents for KLF-200
Page 7: ...6 KLR 200 DIMENSIONS Dimensions are in inches KLF 200 DIMENSIONS Dimensions are in inches...
Page 25: ...24 8 0 ELECTRICAL WIRING DIAGRAMS...
Page 26: ...25...
Page 27: ...26 GeniSys control schematic with the ST9103 Board...
Page 28: ...27 9 0 EXPLODED PARTS VIEW KLR 100 Exploded Parts View...
Page 30: ...29 KLR 200 Exploded Parts View...
Page 32: ...31 KLF 200 Exploded Parts View...