Chapter 4: Installation 

4.1 Safety Requirements 

      Please  read  the  following  safety  items  before  installation  to  avoid 
physical injury and damage to this product or any other products connected. 
To  avoid  potential  hazard,  the  product  can  be  used  only  within  specified 
scope.

  Maintenance  can  be  conducted  only  by  technical  personnel 

authorized by our company. 

 

 
1. Avoid fire or physical injury. 
 
2.  All  power  supply  should  be  shut  off  during  installation,  which  can  be 
turned  on  only  when  all  terminals  have  been  connected  correctly  and 
checked to be free from mistakes.   
 
3. Connect and disconnect in a properly. When device is powered up, do not 
connect or disconnect data cable without due cause. 
 
4.  Grounding.  The  product  should  be  linked  to  the  ground  through  earthed 
conductor.  To  avoid  electric  shock,  the  earthed  conductor  must  be  in 
connection with the ground. Make sure that the product is correctly earthed 
before connecting with the input or output terminals. 
 
5.  Correct  connection.  Users  are  expected  to  use  accompanied  accessories. 
In the event that special connections are needed, please pay attention to the 
corner allocation requirements. 
 
6.    Don’t  operate  when  there  is  no  cover  plate  over  the  device.  Do  not 
operate the product if the cover plate or panel has been dismounted.   
 
7. No contact with bare circuit is allowed. Do not touch bare connectors or 
components when power is on. 
 
8.  No  operation  is  allowed  if  there  is  suspicion  of  failure.  Call  authorized 
maintenance personnel for examination and reparation should the product be 
suspected of damage. 
 
9. Good ventilation. Do not operate under humid or explosive environment. 
 
10. Maintain the surface of the product clean and dry. 

Summary of Contents for OP-4E1+ETH+32Vo

Page 1: ...8 3 6 ETHERNET INTERFACE 9 3 7 SERIAL INTERFACE RS232 RS485 RS422 DATA INTERFACE 9 3 8 FXO FXS TELEPHONE INTERFACE 9 CHAPTER 4 INSTALLATION 10 4 1 SAFETY REQUIREMENTS 10 4 2 INSPECTION UPON UNPACKING...

Page 2: ...contained herein the Company cannot be held liable for any harm or damage resulting from any omissions inaccuracies or errors contained in the manual Brief Introduction This User Manual describes the...

Page 3: ...me temporary construction sites which demand quick solutions to the need of telephone and data operation and the Village village Connection telephone accessing project which is now in progress 1 2 Fea...

Page 4: ...Voice Broadband Optical Multiplexer User Manual 4 1 9 inches structure with 1U height supported high single machine density and lower machine room occupancy...

Page 5: ...eir functions are described as follows Name Color Function Description PWR Green Indication of power supply status on Power supply is OK off No power input SYS Yellow Indication of operating on In nor...

Page 6: ...p off Stand by on for 1s and off for 4s Ringing 2 1 2 CONSOLE Interface Operating parameters of local and remote end devices can be configured through CONSOLE interface and meanwhile operating status...

Page 7: ...ype wires ridding the trouble of remaking the wires 2 2 3 VOICE Interface There are 8 RJ45 ports in a row that are the voice interface each of which can transfer 4 lines of telephone making 1 4 5 8 9...

Page 8: ...o ensure a stable operation Input Voltage AC 220V DC 48V Power Fluctuation 165VAC 265VAC or 36VDC 72VDC Power Consumption 50 W The power consumption will vary in result of the quantity difference of v...

Page 9: ...hone Interface Line Property Comply with the Technical specifications for telephone exchange equipment by Ministry of Posts and Telecommunications Voice encoding PCM encoding 64Kbps per line Relay Int...

Page 10: ...should be linked to the ground through earthed conductor To avoid electric shock the earthed conductor must be in connection with the ground Make sure that the product is correctly earthed before conn...

Page 11: ...wer cable please disconnect the power supply Connect the power supply again after operation And use the equipment under the operating condition required in the manual 4 4 Test The following tests shou...

Page 12: ...that is flat side up from left to right enumerating as 1 2 3 4 5 6 7 8 respectively The following is the allocation of lines The twisted pair specification of RJ 45 is provided as follows EIA TIA568A...

Page 13: ...y use straight through cable the connect method of two ends are the same 2 Connect the equipment and switches or HUB cascadly use cross line cable the connect method of two ends are different Cross li...

Page 14: ...WR is OFF 1 Control switch is not fully turned on 2 The power supply is not connected with correct polarity 3 Outside power source is not correctly plugged 4 Conductor is dropped into the frame causin...

Page 15: ...le properly 2 Change the network structure to reduce the multiple cascades of HUBER 3 Set proper operating mode 4 Set other device clock mode on the line E1 line alarms after the E1 interface is conne...

Page 16: ...m the date of purchase 4 The user fails to provide the certificate of purchase date or the serial number of the product indicates that the product has left the factory 36 months ago 5 Include but not...

Page 17: ...and Optical Multiplexer User Manual 17 not limited to loss of information resulting from defects of the product Product repair maintenance records Name OP 4E1 ETH 32Vo Device Num Repair Date Service N...