Grand Canyon Gas Logs---3435 E. Atlanta Ave---Phoenix, AZ 85040 

 

 

INSTALLATION 

 
The damper clamp with hex bolt is provided as a means to prevent full closure of the damper blade.  The clamp 
is easily attached to most, damper blades with pliers or a wrench, and must be permanently installed.  The 
clamp is designed to prevent accidental closure of the damper when installed.  Should the clamp not fit or fail to 
provide the permanent vent opening listed in the table above, have a permanent stop installed, remove the 
damper blade or have the damper cut to provide the minimum permanent opening required.   

 

The Grand Canyon Gas Log set must be installed by a qualified professional service technician.  Instructions must 
be followed carefully to ensure proper performance and full benefit from the gas log set.  Check to be sure the 
log set is designed and labeled for the type of gas (natural or propane) supplied to the fireplace.  Fireplace floor 
must be level clear of debris and smooth.   

 

WARNING:  Failure to position the parts in accordance with this manual or failure to use only parts specifically 
approved with this appliance may result in property loss, personal injury, or loss of life.   

 

BURNER INSTALLATION: 

1.

 

Make sure the fireplace gas supply is turned off 

2.

 

Locate the gas-supply stub inside the fireplace and remove the cap.  When removing the cap make sure 
the stud does not turn, loosening the connection inside the wall. 

3.

 

Center the burner from side to side and position it as close to the back wall of the firebox.  Ideally, the 
burner will be aligned directly under the flue damper.   

4.

 

Use the 3/8” aluminum flex line connector to connect the gas supply line to the gas inlet on the 
burner/valve.  When bending the aluminum flex line use proper bending procedures to avoid kinking 
the tubing.   

5.

 

Verify that connections are tight, then turn on the gas and check each connection using soap and water 
solution.  DO NOT USE AN OPEN FLAME FOR LEAK TESTING.  The soap and water connection should be 
50% water and 50% soap. Brush the solution over the connections and check for bubbles.  Any leak 
must be corrected prior to proceeding with installation.   

6.

 

Determine the valve system that is installed on the appliance, then proceed with lighting the pilot ( 
NOTE: Manual on/off valves do not have a pilot).   

7.

 

Before lighting the appliance make sure the heat shield is placed back in the position it was when the 
appliance was taken out of the box.   

BURNER MEDIA INSTALLATION: 

1.

 

Locate vermiculite (LP units only) and the rock wool (Glowing Embers).  Vermiculite is used for all 
propane units.   

a.

 

Open the vermiculite, then evenly fill the entire ember pan area, 

2.

 

Open the bag of rock wool, then spread it evenly throughout the entire ember pan area.  Tear the rock 
wool into smaller pieces and keeping it loosely packed will provide a better ember bed appearance.    

 
 
 
 
 
 
 
 
 

Summary of Contents for KIVABRN-18

Page 1: ...ier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach the gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Grand Canyon Gas Log sets are to be installed only in a solid fuel burning fireplace with working flue and construction of noncombustible material The installation incl...

Page 2: ...rovisions for combustion air are provided the screen shall have an opening s for introduction of combustion air With use of glass doors doors must be open while the appliance is burning to assure proper ventilation 7 The minimum inlet supply pressure for the purpose of input adjustment is 5 0 inches natural gas 8 0 inches propane in water column The maximum inlet supply pressure is 10 5 inches nat...

Page 3: ...3 Grand Canyon Gas Logs 3435 E Atlanta Ave Phoenix AZ 85040 MINIMUM CHIMNEY HEIGHT AND FLUE OPENING ...

Page 4: ...d a dark dense material Soot will also accumulate on the logs if the logs are not placed in the proper position according to the log placement diagrams To clean off soot use an old tooth brush and gently rub away the soot Periodic examination and cleaning of the venting system and the solid fuel burning fireplace including frequency of such examination and cleaning by a qualified agency Periodic e...

Page 5: ...e cap When removing the cap make sure the stud does not turn loosening the connection inside the wall 3 Center the burner from side to side and position it as close to the back wall of the firebox Ideally the burner will be aligned directly under the flue damper 4 Use the 3 8 aluminum flex line connector to connect the gas supply line to the gas inlet on the burner valve When bending the aluminum ...

Page 6: ...and to replace any part of the control system and any gas control which has been underwater LIGHTING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 3 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow ...

Page 7: ... Heat Shield 4 110 3 8 Flare x 3 8 Adaptor 5 401 3 8 x Male 6 120 PB Mounting Bracket 7 426 3 8 x 3 Swivel Nut 8 660 Parts Bag 9 102 Pilot Assembly 10 101 Stem 11 229 10 Black Flex line Not Shown SPLPK 1 Vermiculite 2 460 Air Mixer Orifice 3 218P LP Orifice VALVE PARTS LIST 1 8 7 2 3 9 4 3 10 5 6 1 2 3 ...

Page 8: ...8 Grand Canyon Gas Logs 3435 E Atlanta Ave Phoenix AZ 85040 18 24 30 ARIZONA WEATHERED OAK LOG PLACEMENT DIAGRAM ...

Page 9: ...9 Grand Canyon Gas Logs 3435 E Atlanta Ave Phoenix AZ 85040 18 24 30 ARIZONA JUNIPER LOG PLACEMENT GUIDE CON T ...

Page 10: ...ement will be available for pick up from the dealer at which the burner was originally purchased Burners installed outside carry a 1 year warranty This warranty is limited to original purchaser only Electrical and Valves Grand Canyon Gas Logs valves pilot assemblies and electrical components carry a 2 year warranty against breakage or defects from date of purchase by original purchaser and must be...

Reviews: