background image

6

 

Grand Canyon Gas Logs---3435 E. Atlanta Ave---Phoenix, AZ 85040 

 

FOR YOUR SAFETY READ BEFORE LIGHTING 

 

“WARNING – 

If you do not follow these instructions exactly, 

a fire or explosion may result causing property damage, 

personal injury or loss of life.” 

A.

 

This appliance has a pilot which must be 
lighted by hand.   

B.

 

BEFORE LIGHTING

 smell all around the 

appliance area for gas.  Be sure to smell 
next to the floor because some gas is 
heavier than air and will settle on the 
floor.

 

WHAT TO DO IF YOU SMELL GAS: 

1.

 

Do not try to light any appliance. 

2.

 

Do not touch any electric switch; do not 
use any phone in your building 

3.

 

Immediately call your gas supplier from a 
neighbor’s phone.  Follow the gas 
supplier’s instructions. 

4.

 

If you cannot reach your gas supplier, call 
the fire department. 

C.

 

Use only your hand to push in or turn the 
gas control knob.  Never use tools.  If the 
knob will not push in or turn by hand, 
don’t try to repair it, call a qualified service 
technician.  Force or attempted repair may 
result in a fire or explosion 

D.

 

Do not us this appliance if any part has 
been under water.  Immediately call a 
qualified service technician to inspect the 
appliance and to replace any part of the 
control system and any gas control, which 
has been underwater.    

LIGHTING INSTRUCTIONS  

1.

 

STOP! Read the safety information above on this 
label. 

2.

 

Push in gas control knob slightly and turn clockwise 
to “

OFF” 

 

 

 
 
 
 

 
 
NOTE: Knob cannot be turned from “PILOT” to “OFF” 
unless knob is pushed in slightly.  Do not force. 
 

3.

 

Wait five (5) minutes to clear out any gas. If you 
then smell gas, STOP! Follow “B” in the safety 
information above.  If you don’t smell gas, go to 
next step.   

 

4.

 

Find pilot – follow metal tube from the gas control 
behind the burner. 

 
 
 
 
 
 
5.

 

Turn knob on gas counter-clockwise to arrow in the 
center of the knob.  

6.

 

Push in control knob all the way and hold in. 
immediately light the pilot with a match. Continue 
to hold the control knob in for about one minute 
after the pilot is lit. release knob and it will pop 
back up.  Pilot should remain lit.  If it goes out, 
repeat steps 3-7 

 

If knob does not pop up when released, stop and 
immediately call your service technician or gas 
supplier. 

 

If the pilot will not stay lit after several tries, turn 
the gas control knob to “

OFF”           

and call your 

service technician or gas supplier. 

7.

 

Turn gas control knob counterclockwise to “

ON”

 

 

TO TURN OFF GAS TO APPLIANCE 

1.

 

Turn knob clockwise from “

ON

”           position to the center arrow position.  Push in the gas control knob 

slightly and turn clockwise to “

OFF”.                

Do not force knob.

   

Summary of Contents for KIVABRN-18

Page 1: ...ier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach the gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Grand Canyon Gas Log sets are to be installed only in a solid fuel burning fireplace with working flue and construction of noncombustible material The installation incl...

Page 2: ...rovisions for combustion air are provided the screen shall have an opening s for introduction of combustion air With use of glass doors doors must be open while the appliance is burning to assure proper ventilation 7 The minimum inlet supply pressure for the purpose of input adjustment is 5 0 inches natural gas 8 0 inches propane in water column The maximum inlet supply pressure is 10 5 inches nat...

Page 3: ...3 Grand Canyon Gas Logs 3435 E Atlanta Ave Phoenix AZ 85040 MINIMUM CHIMNEY HEIGHT AND FLUE OPENING ...

Page 4: ...d a dark dense material Soot will also accumulate on the logs if the logs are not placed in the proper position according to the log placement diagrams To clean off soot use an old tooth brush and gently rub away the soot Periodic examination and cleaning of the venting system and the solid fuel burning fireplace including frequency of such examination and cleaning by a qualified agency Periodic e...

Page 5: ...e cap When removing the cap make sure the stud does not turn loosening the connection inside the wall 3 Center the burner from side to side and position it as close to the back wall of the firebox Ideally the burner will be aligned directly under the flue damper 4 Use the 3 8 aluminum flex line connector to connect the gas supply line to the gas inlet on the burner valve When bending the aluminum ...

Page 6: ...and to replace any part of the control system and any gas control which has been underwater LIGHTING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 3 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow ...

Page 7: ... Heat Shield 4 110 3 8 Flare x 3 8 Adaptor 5 401 3 8 x Male 6 120 PB Mounting Bracket 7 426 3 8 x 3 Swivel Nut 8 660 Parts Bag 9 102 Pilot Assembly 10 101 Stem 11 229 10 Black Flex line Not Shown SPLPK 1 Vermiculite 2 460 Air Mixer Orifice 3 218P LP Orifice VALVE PARTS LIST 1 8 7 2 3 9 4 3 10 5 6 1 2 3 ...

Page 8: ...8 Grand Canyon Gas Logs 3435 E Atlanta Ave Phoenix AZ 85040 18 24 30 ARIZONA WEATHERED OAK LOG PLACEMENT DIAGRAM ...

Page 9: ...9 Grand Canyon Gas Logs 3435 E Atlanta Ave Phoenix AZ 85040 18 24 30 ARIZONA JUNIPER LOG PLACEMENT GUIDE CON T ...

Page 10: ...ement will be available for pick up from the dealer at which the burner was originally purchased Burners installed outside carry a 1 year warranty This warranty is limited to original purchaser only Electrical and Valves Grand Canyon Gas Logs valves pilot assemblies and electrical components carry a 2 year warranty against breakage or defects from date of purchase by original purchaser and must be...

Reviews: