Locate the sliver gas control (710-502) as well as the 

(2) black plugs, (1) 49-88 (½” MIP x ½” Flare elbow) & 

(1) 48-88 (½” MIP x ½” Flare Straight) fittings.  Review 

Fig_.  Using proper pipe compound thread, the 48-88 

into the “IN” section of the valve and on the opposite 

side thread in (1) black plug.  Wrench until both fittings 

are tight.  With the “IN” of the valve pointed toward 

you, insert the 49-88 on the left and the black plug on 

the right using proper pipe compound.  Wrench until 

both fittings are tight.  For ALL 2-Burners, Glass Burn-

ers, Kiva Burners, front view and see through the  

49-88 should be point back towards the “IN” of the 

valve. Fig. 1.  For 3-Burners & Jumbo/Jumbo Slimline  

Burners (front view and see through) the 49-88  

should be pointing up at a 45* degree angle. Fig. 2.  

For ALL 2-Burners, Glass Burners, Kiva Burners, front 

view and see through the 49-88 should point back 

towards the “IN” of the valve.  For 3-Burners & Jumbo/

Jumbo Slimline Burners (front view and see through) 

the 49-88 should be pointing up at a 45* degree angle.  

See Fig. 3 to verify.  

Locate the US-4-8 (½” x ½” swivel flare) union fitting.  

With an open ended wrench connect the 49-88 on the 

valve to the gas inlet on the burner and wrench tight, 

see Fig. 4.

Locate the pilot mounting bracket.  This can be found 

on the back of the 2-Burner & Kiva, side of the 3-Burn-

er and Jumbo Series and the pan of the glass burner.  

Screw in using the location holes in the pilot bracket 

with self-tapping or #10-32 machine screws.   

See Fig. 5, make sure that the pilot hood has (1) flame 

pointing towards the thermopile and the other flame 

towards the burner.  

INSTALLATION

For ALL 2-Burners

For ALL 3-Burners

FIG 1

FIG 2

FIG 3

FIG 4

FIG 5

Summary of Contents for MVQMKLP

Page 1: ... fireplace where the unit is installed The installation including provisions for combustion ventilation air and required minimum permanent vent opening must conform with the National Fuel Gas Code ANSI Z223 1 NFPA 54 and applicable local building codes In Canada the installation must conform with the Natural Gas and Propane Storage and Handling Instal lation Code CSA B 149 1 A damper stop clamp is...

Page 2: ...llation 5 Installation 6 Operating Instructions 8 Procedure for Lighting or Relighting 9 Service Instructions 10 Troubleshooting 12 Warranty 13 NOTE Changes may change without notice Changes will be shown on updated versions TABLE OF CONTENTS SPECIFICATIONS Refer to the burner owner s manual for minimum firebox dimensions Model BTUs N G L P 70k 112k MVQM MAX BTU OUTPUT ...

Page 3: ...EM WITH THE GLASS DOORS FULLY OPEN BOTH SIDES IF THE FIREPLACE IS A SEE THROUGH TYPE This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes Installation of appliances designed for manufactured homes or mobile homes must conform with Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the U S or wit...

Page 4: ...2 MV PILOT 18 18 Millivolt Pilot Assembly NG version 1 2A MV PILOT 18P 18 Millivolt Pilot Assembly LP version 1 3 US 4 8 1 2 x 1 2 Swivel Nut Union 1 4 48 88 Straight Connector 1 2 OD x 1 2 FIB 1 5 49 88 90º Elbow 1 2 OD x 1 2 FIB 1 6 Heat Shield Millivolt Heat Sheild 1 7 1751 016 Valve LP Conversion Kit LP models only 1 3 2 1 6 4 5 ...

Page 5: ...4 GrandCanyonGasLogs com customerservice grandcanyongaslogs com WIRE DIAGRAM MILLIVOLT must beinstalled or valve will not work ...

Page 6: ...tions must be followed carefully when installing to ensure proper performance These instructions must be used as a supplement to the instructions supplied with the Grand Canyon Gas Logs burner system Follow the burner system instructions and make adjustments as appropriate for the addition of a millivolt system Use gas pipe sealing compound that is resistant to all gasses or Teflon tape and apply ...

Page 7: ...all amount on the male pipe threads Leave the first two threads clean Never use com pound on female threads as it might be pushed into the control body 6 The gas valve is multiposition and can be mount ed in any position except upside down without affecting its operation 7 Install gas valve so gas flow conforms with the inlet and outlet of the control 8 DO NOT insert any object other than suitable...

Page 8: ... the 49 88 should be pointing up at a 45 degree angle Fig 2 For ALL 2 Burners Glass Burners Kiva Burners front view and see through the 49 88 should point back towards the IN of the valve For 3 Burners Jumbo Jumbo Slimline Burners front view and see through the 49 88 should be pointing up at a 45 degree angle See Fig 3 to verify Locate the US 4 8 x swivel flare union fitting With an open ended wre...

Page 9: ...nd phone number DO NOT go back into the building If help is coming wait for them to arrive If L P tank runs out of fuel turn off gas appliance After L P tank is refilled appliance must be relit according to manufac turer s instructions If the gas control has been exposed to WATER in any way DO NOT try to use it It must be re placed DO NOT attempt repair on gas valve or appliance Tampering is DANGE...

Page 10: ... the automatic pilot The Gas Cock Dial cannot be turned to OFF position without first depressing dial in PILOT position and then rotating to OFF 1 Depress and turn Gas Cock Dial to OFF position 2 Turn temperature dial hydraulic models or wall thermostat 24V and millivolt models to OFF or lowest setting 3 Wait at least 5 minutes 10 minutes for L P gas to allow gas which may have accumulated in burn...

Page 11: ...or explosion may result caus ing property damage personal injury or loss of life LIGHTING INSTRUCTIONS FOR MILLIVOLT VALVE 1 STOP Read the safety information above on this label 2 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 3 Wait five 5 minutes to clear out any gas If you smell gas STOP Fol...

Page 12: ...ORTANT Do not use GAS COCK DIAL to adjust gas output on 710 models REGULATOR CONVERSION OR REPLACEMENT CAUTION Main burner and pilot orifices must be changed when regulator is converted from one type of gas to another 710 Series valves can be converted from nonregulat ed to regulated operation by adding one of the 1751 Series regulators To convert from regulated to nonreg ulated order Part Number ...

Page 13: ...inals b Batteries too low for voltage output c Defective valve a Make sure all wire leads are tight and attached to proper terminals see wiring diagram section pg 4 b Replace with new ones c Replace valve 4 Burner system not burning properly a Low flame uneven flame a Check for low gas pressure should have operating pressures of 5 w c for natural gas 11 w c for propane at manifold 5 Burner system ...

Page 14: ...inal purchaser only Indoor burners installed outside carry a 1 year warranty Electrical and Valves Grand Canyon Gas Logs valves remotes receivers carry a 2 year warranty against breakage or defects from date of purchase by original purchaser and must be installed be a licensed profes sional installer This warranty only covers use with Grand Canyon Gas Logs burners and logs In the event a defect or...

Page 15: ...ALL US FIRST For immediate help with installation product information or if your product arrives damaged please call our toll free number at 1 602 344 4217 Monday Friday 8 00AM 5 00PM AZ Mountain Time or email us at customerservice grandcanyongaslogs com OUR STAFF IS READY TO PROVIDE ASSISTANCE ...

Page 16: ...of enjoyment of our products Take a look at our other products from our RPG Brands family of companies Copyright 2022 RPG Brands Grand Canyon Gas Logs All rights reserved Products and specifications subject to change without notice The product images shown are for illustration purposes only and may not be an exact representation of the product ...