Figure 1: Natural Gas
info@grandeffectsinc.com
www.grandeffectsinc.com
949-697-5270
2
Grand Effects
360 Fire-Water Bowls and Fire-Water Inserts (Automated Operation)
Operating and Maintenance Instructions
Section 2: Installation
WARNING!
This unit is for outdoor use only.
Recommended CSA/AGA Clearances: Sides 4 ft / Top 6 ft
Do not install near any combustibles,
such as wood structures, fuels, clothing, fabrics,
or dry vegetation.
A LP gas regulator should never be installed in the fire bowl.
It should be installed by a
gas expert in a remote location away from the heat source.
Install bowls out of the way of pedestrian traffic.
Installation shall be performed by a licensed contractor. All aspects of installation must
conform to local or national codes, or in the absence of codes, with Natural Fuel Gas
Code ANZI Z223.1.
The control panel and approved gas valve must be located where they can be easily
accessible so that the gas can be shut off quickly in case of an emergency.
1.
Install the control panel and gas piping as shown in Figure
1: Natural Gas,
Figure
2:
Propane Gas,
or Figure 3:
Commercial Installation. Gas lines must be
clean and free of any dirt, debris, or contamination.
Note:
Propane piping is different than natural gas piping (shown in Figure
1 and
Figure
2).
2.
The gas piping must be installed underground between the control panel and the
360 fire-water bowl,
as shown in Figure
1.
12 VAC
12 VAC