ELECTRICAL CONNECTION
WARNING!
The connections to the equipment must be carried out by a qualified installer trained by the
manufacturer, in the presence of an electrical technician able to make the electrical connections
required.
WARNING!
For appliances with steam supply, make sure that the electrical connection cable cannot come into
contact with the steam supply pipe or condensation collection/recovery pipe.
WARNING!
For each appliance, an independent circuit must be used. The electrical installation of the laundry
facility must include a differential switch (RCD) type B and an automatic disconnection device
(laundry distribution unit).
IMPORTANT!
The electrical connection must be carried out in compliance with the rules in force in the country of
installation.
IMPORTANT!
Power the appliance in accordance with its rating plate data, and check the distribution system for
correctness.
EARTHING CONNECTION
WARNING!
The appliance must be connected to the protective earthing system of the room where it is installed,
using an independent conductor.
The appliance described in this manual is set up for a
“TT”
earthing system.
To perform a
protective earthing connection
, follow this procedure:
STEAM AND CONDENSATE CONNECTION
(ONLY FOR APPLIANCES WITH STEAM HEATING)
Model
Inlet size
Steam type
Incoming steam
pressure
All models with
steam heating
M 3/4" threaded
dry saturated
50 KPa
÷
600 KPa
Provide for a valve to disconnect the appliance in case of maintenance or failure.
Insert the supplied filter with F/F 3/4” thread between the steam valve and the appliance inlet.
IMPORTANT!
The recommended pressure for the appliance optimal performance ranges from 400KPa to 600KPa.
WARNING!
If the system pressure values are different from those specified, please contact the Manufacturer.
WARNING!
Coat the steam inlet and/or condensate outlet hose with the insulating sheath supplied to prevent
the operator from getting burnt.