P5
Bearing greasing
ONLY for models >GWH28 or GWN-M28
P6
Routine
maintenance
Default factory values. Modify them according to the real conditions of the
equipment.
P7
Extraordinary
maintenance
Default factory values. Modify them according to the real conditions of the
equipment.
6.16 S16 CONNECTIONS
Menu managed by the manufacturer of the appliances. It determines which and how many electronic power
boards must be connected to GUIDO
®
control.
6.17 S17 PRE-SET
This menu allows you to format all the values set in the previous menus, reinitialising GUIDO
®
control.
Selection is 0/1 where 1 allows you to proceed in reinitialising the control.
Attention!
•
The appliance cannot be used after reinitialisation without having
reset all the previous menus.
Once you have reinitialised the control, set the following data to be able to use the appliance:
•
Set the required language via the S3 menu;
•
Reset the type of appliance used with the S9 menu;
•
Set the type and power supply voltage of the inverter with the S14 menu. Proceed with writing the pa-
rameters;
•
Calibrate the pressure switch and the weighing of the S15 menu.
Attention!
•
Exit the SERVICE menu every time a value is set, select the "SAVE DATA"
option and access the SERVICE menu again to proceed with the other
settings.
6.18 S18 DATE/TIME
This menu allows you to set the date and time. These values will be used by GUIDO
®
to record any functional
anomalies, delayed starts and/or maintenance requests.
Attention!
•
GUIDO
®
is not set to automatically adjust the clock according to day-
light savings time;
•
GUIDO
®
does not manage leap years.