5. Specifications
5.1 Thermo Shaker PHMP/PHMP-4 provides:
·
soft or intensive sample shaking;
·
rotation speed control, stabilisation and display;
·
even shaking amplitude throughout the Thermo shaker platform;
·
required operation time setting and display;
·
automatic stopping of the platform movement after the set time expires;
·
current operation time display;
·
setting and display of the required temperature.
5.2 Temperature specifications
·
Temperature setting range ......................................................+25°C ... +60°C (increment 0,1°C)
·
Temperature control range ........................................................................5°C above RT to +60°C
·
Temperature stability............................................................................................................±0.1°C
·
Temperature accuracy .........................................................................................................±0.5°C
·
Temperature uniformity at +37ºC .......................................................................................±0.25°C
·
Time of block heating from +25°C to +37ºC ........................................................................12 min
5.3 General specifications
·
Speed setting range ................................................................250–1200 rpm (increment 10 rpm)
·
Orbit .......................................................................................................................................2 mm
·
Display..................................................................................................................16x2 signs, LCD
·
Digital time setting range ........................................................................1 min – 96 hrs / non-stop
·
Max. continuous operation time............................................................................................96 hrs
(recommended interval between operation sessions not less than 8 hrs)
·
Time setting resolution ...........................................................................................................1 min
·
Max. height of miocroplate...................................................................................................18 mm
·
External power supply ............................................ input AC 100-240 V 50/60Hz, output DC 12V
PHMP
PHMP-4
·
Current/power consumption
12 V DC, 3.3 A / 40 W
12 V DC, 4.15 A / 50 W
•
Platform loading capacity
2
4
•
Platform plate dimensions
250x150 mm
210x290 mm
•
Dimensions
270x260x125 mm
380x390x140 mm
•
Weight*
6.1 kg
8.8 kg
•
The product is designed for operation indoors in a laboratory at altitudes up to 2000 m, with ambient
temperature from +4°C to +40°C and maximum relative humidity 80% for temperatures up to 31°C
decreasing linearly to 50% relative humidity at 40°C.
* Accurate within ±10%.
Grant is committed to a continuous programme of improvement, specifications may be changed without
notice.
Page 9
Thermo shaker PHMP/PHMP-4
Operating instructions
Version 2.03 - July 2013