5
Flat Roof System Installation
20
Flat Roof System
Installation
a
b
5.2 Flat Roof System
Installation
1. Lay mounting rails on the installation
surface with the wide groove
uppermost. Mounting rail interval
= 1770mm.
Diagonal dimensions between
mounting rails must be equal:
D1 = D2
2. Open out a prefabricated flat roof
mounting bracket and place the
long L-profile on the mounting rail
so that the T-profile points
backwards. For interval a, see Page
9, 3.2 Flat roof installation.
3. Fix the flat roof mounting bracket to
the mounting rail using the
interlocking bolts, serrated washers
and nuts provided.
Note:
Interlocking bolts must be secured
to the mounting rail using a 90°
turn.
4. Place the next flat roof mounting
bracket on the mounting rail and fix
using the interlocking bolts. Do not
tighten the bolts too tightly, as final
adjustment may be required. For
interval b, see Page 9, 3.2 Flat roof
installation.
D1
D2
a
04
04
1770
SW 13
Figure 40:
Installation of the First Flat
Roof Mounting Bracket
Figure 42:
Installation of the Second
Flat Roof Mounting Bracket
Figure 41:
Fixing Using Interlocking Bolt