12
Boiler operates.
4.1 Introduction
The appliance comes complete on one pallet, this consists of
the boiler, burner, intermediate hopper (fitted with pellet feed
auger) and combined fan box & flue starter (complete with
exhaust fan and draught stabilizer packed inside the boiler).
Check the packing list (supplied in the boiler) to ensure all
items were delivered.
The Grant SPIRA condensing wood pellet flue system comes
separately and its configuration will depend on the installation
requirements.
4.2 Boiler Location
The boiler must be installed in a damp free environment.
Refer to section 2.4 for boiler and hopper clearances. These
clearances are to allow for access during servicing. Also if
fitting a bulk hopper system refer to section 3.2.2 as the
location of the bulk hopper can influence the boiler location.
4.3 Regulations to comply with
Installation of a Grant wood pellet boiler and hopper must be
in accordance the following recommendations;-
All National Building Regulations and any local
Byelaws which you must check with the local
authority for the area.
Model and local Water Undertaking Byelaws.
The installation should also be in accordance with the
latest edition of the following standard codes of Practice;
BS 715 Metal flue pipes, fittings, terminals and
accessories.
BS EN 12828:2003. Heating systems in buildings.
Design for water-based heating systems
BS EN 12831:2003. Heating systems in buildings.
Method for calculation of the design heat load.
BS EN 14336: 2004.
Heating systems in buildings.
Installation and commissioning of water based
heating systems.
BS 7593 Code of Practice for treatment of water in
heating systems.
BS 7671 Requirements for electrical installations,
IEE wiring regulations.
The ONORM M7137 standard should be used as a guideline
for DIY bulk storage units.
4.4 Preparation for installation
With the units on the pallet, remove all outer packaging from
the units.
Open the boiler front cleaning door and remove the ash-pan
and all items from the combustion chamber.
Remove the packing list and check all items are present.
Fit the ash-pan in place in the combustion chamber and close
the front cleaning door.
4 Installation Information
Summary of Contents for Spira 6-26kW
Page 3: ...3 Grant SPIRA Condensing Wood Pellet Boiler Intermediate Hopper ...
Page 26: ...26 NO 1 NO 2 NO 3 GRANT WOOD PELLET 6 26 9 36 BURNER WIRING DIAGRAM FIGURE 7 4 ...
Page 53: ...53 12 Spare parts 12 1 Burner Burner controls Exploded view Fig 12 1 ...
Page 54: ...54 Burner Brazier Exploded view Fig 12 2 ...
Page 56: ...56 12 2 Boiler Exploded view Fig 12 3 SPIRA 6 26 boiler displayed Boiler parts list ...