51
11.3.4
SAFETY BOILER THERMOSTAT
Notes;
1. The pocket is located within the boiler control panel. Remove control panel outer cover to gain access.
2. Ensure the heating thermistor is retained in the heating pocket using the clip supplied.
3. Continuity can be checked between T1 & T2 of the seven way male connector plug fitted to the side of the
burner.
4. The boiler comes complete with an air vent to vent the secondary heat-exchanger. The primary heat-
exchanger needs to be vented on the heating flow pipe. Check flow is adequately vented.
11.3.5
PROBE FAILURE THERMISTOR
Notes;
1. See diagram 9.3.1
11.3.6
AIR PRESSURE ERROR
CHECK HEATING
THERMISTOR
FITTED IN
YES
NO
NO
YES
REFIT HEATING
THERMISTOR AND
RESET
OVERHEAT
RESET
OVERHEAT STAT
CHECK
CONTINUITY
REPLACE
OVERHEAT
STAT'
IS BOILER
VENTED
CORRECTLY
NO
VENT BOILER
1
2
3
6
5
4
!
SET
RESET
SET 60°C
H2o 60°C
SAFETY BO
Error symbol
SAFETY BOILER THERMOSTAT (OVERHEAT)
note 1
note 2
note 3
note 4
= PRIMARY FAULT
= SECONDARY FOLLOW ON CHECKS
CHECK BURNER
PLUG
CONNECTIONS
CORRECT
YES
NO
REMAKE
CONNECTION
CHECK HEATING
THERMISTOR FOR
DAMAGE
YES
REPLACE
THERMISTOR
NO
CHECK HEATING
THERMISTOR
CONNECTION ON
BURNER PCB
1
2
3
6
5
4
!
SET
RESET
SET 60°C
H2o 60°C
PROBE FAI
Error symbol
PROBE FAILURE THERMISTOR
note 1
= PRIMARY FAULT
= SECONDARY FOLLOW ON CHECKS
Summary of Contents for Spira 6-26kW
Page 3: ...3 Grant SPIRA Condensing Wood Pellet Boiler Intermediate Hopper ...
Page 26: ...26 NO 1 NO 2 NO 3 GRANT WOOD PELLET 6 26 9 36 BURNER WIRING DIAGRAM FIGURE 7 4 ...
Page 53: ...53 12 Spare parts 12 1 Burner Burner controls Exploded view Fig 12 1 ...
Page 54: ...54 Burner Brazier Exploded view Fig 12 2 ...
Page 56: ...56 12 2 Boiler Exploded view Fig 12 3 SPIRA 6 26 boiler displayed Boiler parts list ...