2.2 Boiler output data
Settings in the table below are based on the boiler using the Grant fixed angle pellet feed auger at 45° and an auger
motor fixed speed of 8.5 rpm
using 6mm „BNM Premium ‟, 6mm „Balcas Brites‟ or 6mm „GWP‟ pellets
.
For settings on other brand pellets contact Grant Engineering
.
2.2.1 Burner settings
Model
Pellet
feed
Auger
angle
MAX flame
MIN flame
Burner setting
Heat Output
Heat Input
Burner
setting
Heat Output
’TIME
LOAD
MAX
’TIME
PAUSE’
kW
Btu/h
kW
Btu/h
Full
Eff.
Input
kg/hr
*
’TIME
PAUSE
MIN’
kW
Btu/h
SPIRA
6-26
45°
0025
(2.5sec)
0025
(2.5sec)
26.3
89,735
27.1
92,510
97.4
5.70
0175
(17.5sec)
6.5
22,100
SPIRA
9-36
45°
0065
(6.5sec)
0025
(2.5 sec)
36
122,832
38.7
132,078
93.1
7.78
0250
(25sec)
9
30,700
1. * = Based on a calorific value of 4.81 kW/kg
2. Data given above is approximate only.
3. The above settings will have to be adjusted on site for correct operation of burner.
4. The installer must amend the boiler data label if the output is changed.
2.3 Flue Gas Analysis
Only use a calibrated flue gas analyser that has
a „Wood Pellet‟ fuel setting. Setting the fuel to
an alternative fuel will give incorrect readings.
To allow the boiler to be commissioned and serviced,
the boiler is supplied with a test point in the top cleaning
door. When this test point is used, note that the test
point is for CO
2
and smoke reading only.
The boiler efficiency and flue gas analysis must be taken
from the flue test point that is closest to the flue
connection chamber on the top rear cleaning door. To
gain access to this test point, remove the top panel from
the boiler.
NOTE
!
Do not sample flue gases through the
draught stabilizer or within the flue as the
gases will have been diluted with air from the
draught regulator
. Only
use the test points in
the top rear access door
CAUTION
!
To obtain good combustion the minimum
„TIME LOAD MAX‟ setting should not be set
lower than 25 (2.5 seconds)
CAUTION
!
Summary of Contents for Spira 6-26kW
Page 3: ...3 Grant SPIRA Condensing Wood Pellet Boiler Intermediate Hopper ...
Page 26: ...26 NO 1 NO 2 NO 3 GRANT WOOD PELLET 6 26 9 36 BURNER WIRING DIAGRAM FIGURE 7 4 ...
Page 53: ...53 12 Spare parts 12 1 Burner Burner controls Exploded view Fig 12 1 ...
Page 54: ...54 Burner Brazier Exploded view Fig 12 2 ...
Page 56: ...56 12 2 Boiler Exploded view Fig 12 3 SPIRA 6 26 boiler displayed Boiler parts list ...