12. Fit the three remaining screws (previously removed) in the holes along the front edge of the
grille and tighten all six screws to secure the grille and pellet dam plate in position. Refer to
Figure 4-18.
IMPORTANT: ENSURE THAT SCREWS ARE NOT DROPPED INSIDE THE HOPPER!
13. Locate the door stay in the slot (on left hand side) and check the door opens and closes
correctly. Refer to Figure 4-19.
4.3 Flexible Pellet Tubes
Two flexible tubes must be used to connect the Vacuum unit (on the pellet hopper) to the Auger unit (on
the bulk pellet store).
IMPORTANT:
The connection marked ‘VACUUM FLOW’ on the auger unit MUST be connected to the corresponding
‘VACUUM FLOW’ connection on the vacuum unit. Similarly, the ‘VACUUM RETURN’ connections on the
auger and vacuum units must be connected together.
All connections must be made using the following procedure:
1.
Cut the two flexible tubes to the required length.
2. Cut back the tube at each end to expose approximately 40-50mm of the copper anti-static
wire. Refer to Figure 4-20.