background image

 

 

 

PHOTOVOLTAIC MODULES SAFETY 

AND INSTALLATION MANUAL Rev. K 

VALID IN NORTH AMERICA ONLY 

Valid from September 2010 

1305 S. Bertelsen Road Eugene, OR 97402 

www.grapesolar.com 

Tel: 1-877-264-1014 (toll free), 1-541-349-9000, Fax: 1-541-343-9000 

 

 

III.

 

MODULE INSTALLATION 

1.

 

Installation Site Selection 

1.1

 

The site for PV module installation shall have environment temperature within Grape Solar’s 
PV module operating temperature range -40°C to +80°C (-40°F to +176°F).   

1.2

 

The site shall allow all modules to be exposed to sunlight without obstruction all year round 
(shadows generated by trees or buildings, even partial shading, on the module array will result 
in reduction of PV system yield). 

1.3

 

The site shall have adequate ventilation of the module backside to avoid heat build-up, which 
can cause module performance degradation and system yield reduction. For roof mounted 
systems, at least a 2 inch clearance is required between the module back surface and roof for 
rear ventilation and module cooling. 

1.4

 

The modules are designed to have maximum mechanical load at 2400 Pascal (50 lbs/ft

2

). To 

avoid exceeding the maximum load, site specific loads such as wind and snow should be taken 
into account. 

1.5

 

The site should not have exposure to extremely corrosive chemicals (e.g. emissions from 
manufacturing facilities). 

2.

 

Module Orientation & Tilt Angle 

2.1  To obtain maximum yield from the PV system, the direction and tilt angle for the modules shall 

be set to receive the incident sunlight perpendicularly to the module surface. To avoid 
performance degradation in serial connected module strings, all modules shall have the same 
orientation and tilt angle. 

2.2  To avoid dirt build-up on the glass against the frame edge, low module tilt angle is not 

recommended. Dirt build-up on the module surface can cause partial shading and degrade 
module and system electrical performance.

 

3.

 

Electrical Connection 

3.1

 

All installations must be performed in compliance with the National Electrical Code (NEC) and 
any applicable local codes by authorized personnel. If the module is installed in Canada, 
installation shall be in accordance with CSA C22.1, Safety Standard for Electrical Installations, 
Canadian Electrical Code, Part 1. 

3.2

 

Modules may be connected in series and/or in parallel to achieve the desired electrical output. 
When serial connected, all modules must have the same amperage, but the maximum open 
circuit voltage of the system must not exceed the specified maximum system voltage of the 
modules. When parallel connected, all modules must have the same voltage. 

Summary of Contents for CS-P-200-DJ

Page 1: ...odules with model number CS S 160 DJ CS S 165 DJ CS S 170 DJ CS S 175 DJ CS S 180 DJ CS P 200 DJ CS P 210 DJ CS P 220 DJ CS P 230 DJ CS P 240 DJ CS P 250 DJ CS P 260 DJ CS P 270 DJ and CS P 280 DJ Car...

Page 2: ...from September 2010 1305 S Bertelsen Road Eugene OR 97402 www grapesolar com Tel 1 877 264 1014 toll free 1 541 349 9000 Fax 1 541 343 9000 Table of Contents I General Information 3 II Safety Precauti...

Page 3: ...door land based applications only 6 Rated power output specification of Grape Solar PV modules are made at the Standard Test Condition STC which is 1000W m2 irradiance 1 5 Air Mass AM and 25 C 77 F ce...

Page 4: ...cted modules have to be stored outside for any length of time always have the glass surface facing down and cover modules with water proof material to prevent water collecting inside the panel and cau...

Page 5: ...hen working with modules exposed to light follow all applicable regulations regarding working with live electrical equipment 3 5 Do not install or handle the modules when they are wet or during period...

Page 6: ...connections 3 15 Broken junction boxes or broken connectors are electrical and laceration hazardous and cannot be repaired Please contact the installers to remove the broken module from the array and...

Page 7: ...n into account 1 5 The site should not have exposure to extremely corrosive chemicals e g emissions from manufacturing facilities 2 Module Orientation Tilt Angle 2 1 To obtain maximum yield from the P...

Page 8: ...ach module or string of modules when reverse current is anticipated to exceed the value of the module protective fuse 3 8 The junction box contains factory installed 3 bypass diodes and is not designe...

Page 9: ...ay be mounted at any angle from vertical to horizontal orientation However to obtain maximum yield from the PV system the direction and tilt angle for the modules shall be set to receive the incident...

Page 10: ...they have been evaluated by UL for mounting At least four stainless steel screws of the 10 22mm the stainless steel nuts and washers of 10mm are required to mount the module securely It is recommended...

Page 11: ...not remove the dirt by scraping or rubbing away from the module front surface when dry as this may cause micro scratches on the glass and lead to module performance degrading 5 Water can be used for...

Page 12: ...injury or expense arising through improper use or incorrect installation operation or maintenance Furthermore Grape Solar assumes no responsibility for any infringement of patents or other rights of t...

Page 13: ...1 877 264 1014 toll free 1 541 349 9000 Fax 1 541 343 9000 Appendix Figure 2 Position of Mounting Holes Model CS S 160 DJ CS S 165 DJ CS S 170 DJ CS S 175 DJ and CS S 180 DJ Figure 3 Position of Moun...

Reviews: