PHOTOVOLTAIC MODULES SAFETY 

 

AND INST

 

ALLATION MANUAL Rev. 

 

P

 

 

 

VALID IN NORTH AMERICA ONLY

 

 

 

 

 

 

 

 

 

 

 

1  Stainless steel M5 nut 

 

2  Stainless steel cupped M5 washer 

 

 

 

34  Stainless steStainless steeel l flat M5 M5 

serrated washerwasher  

 

 

5

 

Grounding lead 

 

6

 

Stainless steel M5 bolt 

 

 

 

 

 

        

 

 

 

 

 

Figure-1 Grounding panel frame with stainless steel grounding & bonding equipment

 

 

5.

 

Mounting  

5.1

  

The modules have been evaluated by UL that can sustain a positive or negative design loading 
of 30 lbs/ft

(1600 Pascal). The maximum mechanical load on the module must not exceed 45 

lbs/ft

2

 (2150 Pascal) under any circumstance.  

5.2

  

Each module must be securely fastened at a minimum of 4 points using support frames or 
mounting kits specialized for PV applications.   

5.3

  

Panels may be mounted at any angle from vertical to horizontal orientation. However, to obtain 
maximum yield from the PV system, the direction and tilt angle for the modules shall be set to 
receive the incident sunlight perpendicularly to the module surface.  

5.4

  

For roof mounted systems, at least a 4 inch clearance is required between the module back 
surface and roof for rear ventilation and module cooling.  

5.5

  

Clearance of 1/24 inch (1mm) or more between modules is required to allow for thermal 
expansion of the frames.  

5.6

  

Keep the back surface of the module free from any foreign objects or structural elements which 
could come into contact with the module, especially when the module is under mechanical load.  

Summary of Contents for GS-M60-285-Fab1-US

Page 1: ...ies to Grape Solar photovoltaic modules with model number GS P60 265 Fab1 GS P60 265 Fab2 GS S60LSQ 285 PR GS M60 285 Fab1 US and GS M60 300 Fab1 US Carefully read through this manual in its entirety...

Page 2: ...Tel 1 877 264 1014 toll free 1 541 349 9000 Fax 1 541 343 9000 PHOTOVOLTAIC MODULES SAFETY AND INSTALLATION MANUAL Rev P VALID IN NORTH AMERICA ONLY Table of Contents I General Information 3 II Safet...

Page 3: ...land based applications only 6 Rated power output specification of Grape Solar PV modules are made at the Standard Test Condition STC which is 1000W m2 irradiance 1 5 Air Mass AM and 25 C 77 F cell te...

Page 4: ...tore the modules in a dry ventilated in door space if possible If the un connected modules have to be stored outside for any length of time always have the glass surface facing down and cover modules...

Page 5: ...fety Standard for Electrical Installations Canadian Electrical Code Part 1 3 2 Keep children away from module and the system when installing 3 3 Do not wear metallic jewelry while performing mechanica...

Page 6: ...inals can result in burns sparks and lethal shock whether the module is connected or disconnected 3 14 Cover all modules in the PV array with an opaque cloth or material before making or breaking elec...

Page 7: ...t least a 4 inch clearance is required between the module back surface and roof for rear ventilation and module cooling 1 4 The modules have been evaluated by following UL 1703 standard that can susta...

Page 8: ...ained personnel from disconnecting the modules when under load which may cause serious bodily injury or death all Grape Solar PV modules are equipped with factory installed PV wires and MC 4 comparabl...

Page 9: ...DBT ground lug to either grounding hole at the back of the module Place the ground lug on the module frame s outer surface and in line lengthwise Insert a 8 32 x 0 5 stainless steel screw through the...

Page 10: ...ft2 2150 Pascal under any circumstance 5 2 Each module must be securely fastened at a minimum of 4 points using support frames or mounting kits specialized for PV applications 5 3 Panels may be mount...

Page 11: ...steel screw via each mounting hole with stainless steel flat washer and secure from behind with another stainless steel flat washer local washer and nut Torque the bolts to 6 3ft lbs 8 5Nm 5 9 2 Press...

Page 12: ...Solar assumes no liability for loss damage injury or expense arising through improper use or incorrect installation operation or maintenance Furthermore Grape Solar assumes no responsibility for any...

Reviews: