PHOTOVOLTAIC MODULES SAFETY 

 

AND INST

 

ALLATION MANUAL Rev. 

 

P

 

 

 

VALID IN NORTH AMERICA ONLY

 

 

 

 

 

 

 

3.10 PV modules do not have a power ON/OFF switch. The only way to make modules inoperative is 

removing them from light, or fully covering their front surface with an opaque material, or 
placing modules face down on a smooth, flat surface.  

3.11 Avoid setting the module down with any type of force on any surface, particularly when placing 

it at a corner.  

3.12

 

To prevent untrained personnel from disconnecting the modules after installed, locking 

connectors and safety clips must be used in the installation.   

3.13

 

Do not touch electrical terminals or the ends of any wire while installing the module. Do not open 

electrical connections or unplug connectors while the PV system circuit is under load.

 

Contact 

with electrically active parts of the modules, such as terminals, can result in burns, sparks and 
lethal shock whether the module is connected or disconnected.  

3.14

 

Cover all modules in the PV array with an opaque cloth or material before making or breaking 

electrical connections.  

3.15

 

Broken junction boxes or broken connectors are electrical and laceration hazardous and cannot be 

repaired. Please contact the installers to remove the broken module from the array and contact 
the supplier for disposal instructions.  

4.

 

Fire Safety  

 

4.1   Grape Solar’s PV modules are non-explosion-protected equipment and fire rated Type 1 or Type 

2 (see panel spec sheet).  

4.2   Building fire safety may be affected by installing a PV system. Improper installation may lead to 

hazards in the event of fire. Refer to local authority for guidelines and requirements for building 
or structural fire safety.  

4.3   For roof installation, PV modules should be mounted over a fire resistant covering which is 

rated for the application.  

4.4   Do not install modules near equipment or locations where flammable gases can be generated or 

collected.  

4.5   Grape Solar recommends using components such as earth ground fault circuit breakers, fuses 

and circuit breakers in the PV system for fire prevention.  

Summary of Contents for GS-M60-285-Fab1-US

Page 1: ...ies to Grape Solar photovoltaic modules with model number GS P60 265 Fab1 GS P60 265 Fab2 GS S60LSQ 285 PR GS M60 285 Fab1 US and GS M60 300 Fab1 US Carefully read through this manual in its entirety...

Page 2: ...Tel 1 877 264 1014 toll free 1 541 349 9000 Fax 1 541 343 9000 PHOTOVOLTAIC MODULES SAFETY AND INSTALLATION MANUAL Rev P VALID IN NORTH AMERICA ONLY Table of Contents I General Information 3 II Safet...

Page 3: ...land based applications only 6 Rated power output specification of Grape Solar PV modules are made at the Standard Test Condition STC which is 1000W m2 irradiance 1 5 Air Mass AM and 25 C 77 F cell te...

Page 4: ...tore the modules in a dry ventilated in door space if possible If the un connected modules have to be stored outside for any length of time always have the glass surface facing down and cover modules...

Page 5: ...fety Standard for Electrical Installations Canadian Electrical Code Part 1 3 2 Keep children away from module and the system when installing 3 3 Do not wear metallic jewelry while performing mechanica...

Page 6: ...inals can result in burns sparks and lethal shock whether the module is connected or disconnected 3 14 Cover all modules in the PV array with an opaque cloth or material before making or breaking elec...

Page 7: ...t least a 4 inch clearance is required between the module back surface and roof for rear ventilation and module cooling 1 4 The modules have been evaluated by following UL 1703 standard that can susta...

Page 8: ...ained personnel from disconnecting the modules when under load which may cause serious bodily injury or death all Grape Solar PV modules are equipped with factory installed PV wires and MC 4 comparabl...

Page 9: ...DBT ground lug to either grounding hole at the back of the module Place the ground lug on the module frame s outer surface and in line lengthwise Insert a 8 32 x 0 5 stainless steel screw through the...

Page 10: ...ft2 2150 Pascal under any circumstance 5 2 Each module must be securely fastened at a minimum of 4 points using support frames or mounting kits specialized for PV applications 5 3 Panels may be mount...

Page 11: ...steel screw via each mounting hole with stainless steel flat washer and secure from behind with another stainless steel flat washer local washer and nut Torque the bolts to 6 3ft lbs 8 5Nm 5 9 2 Press...

Page 12: ...Solar assumes no liability for loss damage injury or expense arising through improper use or incorrect installation operation or maintenance Furthermore Grape Solar assumes no responsibility for any...

Reviews: