3.

 

Electrical Connection  

3.1

  

All installations must be performed in compliance with the National Electrical Code (NEC) and 
any applicable local codes by authorized personnel. If the module is installed in Canada, 
installation shall be in accordance with CSA C22.1, Safety Standard for Electrical Installations, 
Canadian Electrical Code, Part 1.  

 

3.2

  

Modules may be connected in series and/or in parallel to achieve the desired electrical output.  

When serial connected, all modules must have the same amperage, but the maximum open 
circuit voltage of the system must not exceed the specified maximum system voltage of the 
modules. When parallel connected, all modules must have the same voltage.  

3.3

  

Do not use modules with different electrical performance or physical properties in the same 
system.  

3.4

  

To prevent untrained personnel from disconnecting the modules when under load, which may 
cause serious bodily injury or death, all Grape Solar PV modules are equipped with factory-
installed PV wires and MC-4-comparable connectors with locking safety clips. Once connected, 
the connector requires the use of a special tool to disconnect module-to-module connections.  

3.5

  

When making module-to-module connections, the polarities of cables and terminals must be 
matched. Failure to do so may result in damage to the module and void the module warranty.  

3.6

  

Use cables and wires with adequate cross-sectional areas (min. of 12AWG) and suitable MC-4-
comparable connectors which are approved for use at the maximum short-circuit current of the 
module.  

3.7

  

Over-current device (e.g. fuse or circuit breaker) whose rating is not greater than the value of the 
protective fuse marked on the back of the module must be serial connected with each module or 
string of modules when reverse current is anticipated to exceed the value of the module 
protective fuse.  

3.8

  

The junction box contains factory installed blocking diodes and is not designed to be field 
accessible or maintainable, and should not be opened under any circumstances. Opening the 
junction box will void the warranty.  

  

Summary of Contents for GS-M60-285-Fab1-US

Page 1: ...ies to Grape Solar photovoltaic modules with model number GS P60 265 Fab1 GS P60 265 Fab2 GS S60LSQ 285 PR GS M60 285 Fab1 US and GS M60 300 Fab1 US Carefully read through this manual in its entirety...

Page 2: ...Tel 1 877 264 1014 toll free 1 541 349 9000 Fax 1 541 343 9000 PHOTOVOLTAIC MODULES SAFETY AND INSTALLATION MANUAL Rev P VALID IN NORTH AMERICA ONLY Table of Contents I General Information 3 II Safet...

Page 3: ...land based applications only 6 Rated power output specification of Grape Solar PV modules are made at the Standard Test Condition STC which is 1000W m2 irradiance 1 5 Air Mass AM and 25 C 77 F cell te...

Page 4: ...tore the modules in a dry ventilated in door space if possible If the un connected modules have to be stored outside for any length of time always have the glass surface facing down and cover modules...

Page 5: ...fety Standard for Electrical Installations Canadian Electrical Code Part 1 3 2 Keep children away from module and the system when installing 3 3 Do not wear metallic jewelry while performing mechanica...

Page 6: ...inals can result in burns sparks and lethal shock whether the module is connected or disconnected 3 14 Cover all modules in the PV array with an opaque cloth or material before making or breaking elec...

Page 7: ...t least a 4 inch clearance is required between the module back surface and roof for rear ventilation and module cooling 1 4 The modules have been evaluated by following UL 1703 standard that can susta...

Page 8: ...ained personnel from disconnecting the modules when under load which may cause serious bodily injury or death all Grape Solar PV modules are equipped with factory installed PV wires and MC 4 comparabl...

Page 9: ...DBT ground lug to either grounding hole at the back of the module Place the ground lug on the module frame s outer surface and in line lengthwise Insert a 8 32 x 0 5 stainless steel screw through the...

Page 10: ...ft2 2150 Pascal under any circumstance 5 2 Each module must be securely fastened at a minimum of 4 points using support frames or mounting kits specialized for PV applications 5 3 Panels may be mount...

Page 11: ...steel screw via each mounting hole with stainless steel flat washer and secure from behind with another stainless steel flat washer local washer and nut Torque the bolts to 6 3ft lbs 8 5Nm 5 9 2 Press...

Page 12: ...Solar assumes no liability for loss damage injury or expense arising through improper use or incorrect installation operation or maintenance Furthermore Grape Solar assumes no responsibility for any...

Reviews: