3-4
Basic Settings and Operations
Setting OFFSET
This setting adjusts the offset of the cutter blade to suit the blade type used. The tip of the blade
mounted in the cutter-pen plunger is not positioned at the center of the pen, so correction is
required. This correction is referred to as the OFFSET setting. The cutting plotter has been preset
with OFFSET values for each cutter-blade type. Selecting
"09U," "15U,"
or
"15B"
for the PEN
TYPE setting also sets the appropriate OFFSET, allowing fine adjustment within the range of
±
5.
When the
"PEN"
setting is selected, the OFFSET cannot be set.
(1) Press the
(COND.) key
in READY mode to display the cutter-pen conditions.
(2) Select the setting area (condition number) to be set, and then use the
or
key
to move
the
s
symbol to the position shown below.
2 0 9 U + 1 2 3 3 0 2
(3) Use the
or
key
to select the value to be changed in the range of
"-5"
to
"+5."
Press the
(ENTER) key
to confirm the selection. If other conditions are to be set, press the
or
key
to move the symbol to the parameter to be set.
Setting FORCE
Sets the pressure applied by the cutter pen during cutting. Set the FORCE value based on the
guidelines in the table entitled "Optimal Cutting Conditions for Each Media Type" on page 3-2.
(1) Press the
(COND.) key
in READY mode to display the cutter-pen conditions.
(2) Select the setting area (condition number) to be set, and then use the
or
key
to move
the
s
symbol to the position shown below.
2 0 9 U + 1 2 3 3 0 2
(3) Press the
or
key
to select the value to be changed in the range specified below.
"1"
to
"31"
Press the
(ENTER) key
to confirm the selection. If other conditions are to be set, press the
or
key
to move the
s
symbol to the parameter to be set.
Setting SPEED
Sets the speed used for cutting. Set the SPEED value based on the guidelines in the table entitled
"Optimal Cutting Conditions for Each Media Type" on page 3-2.
(1) Press the
(COND.) key
in READY mode to display the cutter-pen conditions.
(2) Select the setting area (condition number) to be set, and then use the
or
key
to move
the
s
symbol to the position shown below.
2 0 9 U + 1 2 3 3 0 2
(3) Press the
or
key
to select the value to be corrected in the range specified below.
"1"
to
"60"
;
"*"
"1"
to
"10"
is in increments of 1, and
"10"
to
"60"
is in increments of 5.
Press the
(ENTER) key
to confirm the selection. If other conditions are to be set, press the
or
key
to move the
s
symbol to the parameter to be set.
CHECKPOINT
Selecting
"*"
sets the maximum speed. QUALITY is also set to "*", and the acceleration is calculated