CE5000-UM-251-9370
7-8
7. ELECTRICAL ADJUSTMENTS
7.7 Inputting the Servo Gain
If you replace the main board or the motor, use the following procedure to input the recorded adjustment
values.
How to input the servo gain
(1) Load a cutting sheet in the plotter.
(2) Turn on the power while pressing the TEST and ENTER keys.
(3) Select the media mode.
(4) Press the PAUSE key to display the menu shown below.
MODEL SELECT
(5) Press the NEXT key until the following menu is displayed.
SET GAIN
(6) Press the ENTER key to display the menu shown below.
GAIN X= 80 Y= 50
(7) Input the values that are recorded on the chassis.
(
default factory settings)
Press the UP or DOWN ARROW key to change the X-Gain value.
Press the LEFT or RIGHT ARROW key to change the Y-Gain value.
If the default factory settings were not shown on the label input the following value.
Model
X-Gain
Y-Gain
CE5000-40
32
32
CE5000-60
45
42
CE5000-120/120AP
80
50
(8) Press the ENTER key to store the setting and complete the adjustment.