12-7
Error Messages in HP-GL Command Mode
If any of the followng command errors occur, they are nearly always caused by followng 2 reasons.
1. The configuration regarding the output device in the application software has changed.
2. The plotter's nterface condtons have changed.
Perform followng f these are the cause of the problem.
1. Reconfigure the output device of the application software to the plotter.
2. Reconfigure the plotter's interface conditions.
Error
Displayed
LCD Display
Cause
Solution
E03001
Error 1
An unrecognizable instruction was
executed.
Execute a recognizable command.
E03002
Error 2
Wrong number of parameters were
specified.
Execute the command wth the correct
number of parameters.
E03003
Error 3
An unusable parameter was executed.
Execute a recognizable parameter.
E03005
Error 5
An unusable character set was specified.
Specfy usable character set.
E03006
Error 6
Coordinates of command specified out of
cuttng area.
Execute coordnates wthn the cuttng area.
E03007
Error 7
The data beng nput exceeds the capacty
of the plotter's downloadable character
buffer, polygon buffer, etc.
Adjust the buffer size.
E03010
Error 10
Other output command was executed whle
executng an output command.
Check the program.
E03011
Error 11
An nvald byte was receved after ESC
code.
Check the program.
E03012
Error 12
Invald byte was receved wthn devce
control command.
Check the program.
E03013
Error 13
A parameter outsde of the permssble
range was specified in the I/O related
command.