background image

1/4

New procedure to replace the main board of CE6000

The CE6000 series has a Sub-NVRAM on the cam sensor board.
This Sub-NVRAM is backing up all settings values for the main board.
Therefore all setting values are able to copy from the Sub-NVRAM to the main board without inputting 
adjustment values from the factory adjustment label when the main board is replacing.
This function will help you when you are going to replace the main board of CE6000 series.
Note: This function is supported from the firmware version 1.30.

How to copy the adjustment values from the Sub NVRAM to the main board

(1)  Turn off the power for the CE6000 if the power was on.
(2)  Replace the main board.
(3)  Perform the NV-RAM clear with corresponding model of dip-switch settings.

Set the dip-switch settings with corresponding model to the NV-RAM clear mode.

Dip Switch

1

2

3

4

Model

SW1

1 2 3 4

ON
OFF

OFF OFF OFF ON CE6000-40

SW1

1 2 3 4

ON
OFF

ON OFF OFF ON CE6000-60

SW1

1 2 3 4

ON
OFF

OFF ON OFF ON CE6000-120/120AMO

SW1

1 2 3 4

ON
OFF

ON ON OFF ON CE6000-120AP

(4)  Turn on the power for the CE6000 after the dip-switches were set to the NV-RAM Clear mode.
(5)  Wait until the NV-RAM Clear was finished.
(6)  Turn off the power for the CE6000 when the NV-RAM Clear was finished.
(7)  Set the dip-switch settings with corresponding model to the normal mode.

Dip Switch

1

2

3

4

Model

SW1

1 2 3 4

ON
OFF

OFF OFF OFF OFF

CE6000-40
Old Grid Roller (Right side grid roller width 150 mm)

SW1

1 2 3 4

ON
OFF

OFF OFF ON OFF

CE6000-40
New Grid Roller (Right side grid roller width 160 mm)

SW1

1 2 3 4

ON
OFF

ON OFF OFF OFF CE6000-60

SW1

1 2 3 4

ON
OFF

OFF ON OFF OFF CE6000-120/AMO

SW1

1 2 3 4

ON
OFF

ON ON OFF OFF CE6000-120AP

Reviews: