8 Electrical Adjustment
Factory presets (Normal Mode)
This setting depends on the model.
Dip Switch (SW1)
1
2
3
4
5
6
7
8
Model
1 2 3 4 5 6 7 8
ON
OFF
OFF OFF OFF OFF OFF OFF OFF OFF CE7000-40
1 2 3 4 5 6 7 8
ON
OFF
ON OFF OFF OFF OFF OFF OFF OFF CE7000-60
1 2 3 4 5 6 7 8
ON
OFF
OFF ON OFF OFF OFF OFF OFF OFF CE7000-130
1 2 3 4 5 6 7 8
ON
OFF
ON ON OFF OFF OFF OFF OFF OFF CE7000-160
1 2 3 4 5 6 7 8
ON
OFF
OFF ON ON OFF OFF OFF OFF OFF CE7000-130AP
Note:
The NOV-RAM CLEAR must perform when the dip switch setting was changed from previous model setting.
NOV-RAM Clear
All adjustment values are cleared to the default value of each model when the NV-RAM CLEAR was
performed.
Dip Switch (SW1)
1
2
3
4
5
6
7
8
Model
1 2 3 4 5 6 7 8
ON
OFF
OFF OFF OFF ON OFF OFF OFF OFF CE7000-40
1 2 3 4 5 6 7 8
ON
OFF
ON OFF OFF ON OFF OFF OFF OFF CE7000-60
1 2 3 4 5 6 7 8
ON
OFF
OFF ON OFF ON OFF OFF OFF OFF CE7000-130
1 2 3 4 5 6 7 8
ON
OFF
ON ON OFF ON OFF OFF OFF OFF CE7000-160
1 2 3 4 5 6 7 8
ON
OFF
OFF ON ON ON OFF OFF OFF OFF CE7000-130AP