11-4
Related to GP-GL command
This section is useful only when using the GP-GL command.
Setting the step size (GP-GL STEP SIZE)
The distance to travel with 1 step can be changed. Match the setting value of the application to be used.
Operation
1
Press the [PAUSE/MENU] key in the default screen.
MENU screen is displayed.
Menu screen
(Normal mode)
Menu screen
(Simple mode)
2
Press the POSITION ( ) key (I/F) in Normal mode and press
the POSITION ( ) key in the INTERFACE (I/F) screen.
Press the [2] key (I/F) in Simple mode.
INTERFACE screen is displayed.
INTERFACE screen
(Normal mode)
INTERFACE screen
(Simple mode)
3
Press the [1] key (GP-GL STEP SIZE) in Normal mode or
press the [2] key (GP-GL STEP SIZE) in Simple mode.
GP-GL STEP SIZE screen is displayed.
4
Press the [1] key (0.100 mm), the [2] key (0.050 mm), the [3]
key (0.025 mm), or the [4] key (0.010 mm).
5
Confirm the setting and press the [ENTER] key (SET).
Setting will be confirmed and it will return to INTERFACE screen.
6
Press the [PAUSE/MENU] key.
It will return to default screen.