11-5
Enabling/Disabling the ' : ' and ' ; ' commands (COMMAND ' : ', ' ; ')
If the first part of the data is lost when the GP-GL command is set, these commands may be having an adverse
effect. In this case, set the ' : ' and ' ; ' commands to DISABLED.
Operation
Supplement
Perform the settings in Normal mode.
1
Press the [PAUSE/MENU] key in the default screen.
MENU screen is displayed.
2
Press the POSITION ( ) key (I/F).
INTERFACE screen (1/3) is displayed.
3
Press the POSITION ( ) key.
INTERFACE screen (2/3) is displayed.
4
Press the [4] key (COMMAND ' : ', ' ; ').
COMMAND ' : ', ' ; ' screen is displayed.
5
Press the [1] key (ENABLED) or the [2] key (DISABLED).
6
Confirm the setting and press the [ENTER] key (SET).
Setting will be confirmed and it will return to INTERFACE screen (2/3).
7
Press the [PAUSE/MENU] key.
It will return to default screen.