5-15
Chapter 5 Detailed Settings
Confirming the Registration Marks
Actually detect the registration marks to confirm operation of registration mark detection.
1.
Load the media on which the registration marks have been drawn.
2.
From the "MENU" screen, open the "ARMS
1/2" screen.
3.
Touch the "CHECK MARK SCAN".
4.
Touch the "MARK LINE CHECK".
Scan Starting Position
Registration
Mark
Registration Mark
Type 2
Registration Mark
Type 1
X
Y
Media T
ransport Dir
ection
5.
Select the type of registration marks to scan, use the
"
", " ", "
" and " " to move the tool carriage to the
scan starting position (the position of the red circle in
the image to the right) and touch the (OK).
6.
The tool carriage will move and automatically detect
the registration marks.
7.
The result of the scan will be displayed on the screen.
MARK SCAN MODE: The currently set scan mode will be displayed.
RESULT: The scan result (OK/NG) will be displayed.
It may not be possible to detect the registration marks depending on the state of the base. In such case, run
the "MEDIA CHECK" function and try again with the recommended conditions.
Summary of Contents for CELITE-50
Page 1: ...USER S MANUAL CE LITE 50 UM 151...
Page 2: ......
Page 10: ......
Page 22: ......
Page 78: ......
Page 101: ...5 23 Chapter 5 Detailed Settings 3 Select ON or OFF for WIDTH DETECTION...
Page 112: ......
Page 116: ...A 4 Appendix A 3 Appearance Drawing 164 784 227 173 400 Units mm Dimension error 5 mm...
Page 118: ...A 6 Appendix 3 PIECES Previous Page HOME SELECT FILE...
Page 119: ...A 7 Appendix TOOL ARMS MODE 1 MODE 2 MODE 3 CHECK MARK SCAN SENSOR OFFSET ADJ Next Page MENU...
Page 120: ...A 8 Appendix INTERFACE ADVANCE TEST Previous Page AREA MEDIA MENU...
Page 127: ......
Page 128: ......