5-23
Chapter 5 FUNCTION SETTINGS AND OPERATIONS
5.21 Setting the Step Pass
Use this function when you intend to cut extremely detailed data. The cutting data sent from the computer
will be processed in blocks corresponding to the number of steps speci
fi
ed by the STEP PASS function,
thereby ensuring consistent blade control and higher cutting quality.
(1) Press the
[PAUSE] key
to select PAUSE mode.
(2) Press the
[NEXT] key
repeatedly until the following menu is displayed.
FORCE
OFFSET
SPEED
QUALITY
OPTION1 OPTION2
(3) Press the
[F2] key
(OPTION1) to display the menu shown below.
FORCE
OFFSET
SPEED
QUALITY
START FCE OFST ANG
OFST FCE STP PASS
(4) Press the
[F4] key
(STP PASS) to display the step pass setting screen.
FORCE
OFFSET
SPEED
QUALITY
STEP PASS
STEP PASS = 1
Use
the
[
]
or
[
]
key
to change the numeric value, and then press the
[ENTER] key
to con
fi
rm your selection.
Setting range: 0 to 20 [Default value: 1]
1
0
2
18
19
20
If the STEP PASS setting is set too high, the cut shapes may become deformed. The recommended STEP PASS
setting is "STEP PASS= 1".
(5) Press the
[PAUSE] key
to cancel PAUSE mode.
This setting is retained in the plotter's internal memory even while the plotter is turned off.
Summary of Contents for CUTTING PRO FC2250 Series
Page 1: ...USER S MANUAL MANUAL NO FC2250 UM 151 FC2250 SERIES CUTTING PRO www delinit by...
Page 104: ...5 29 Chapter 5 FUNCTION SETTINGS AND OPERATIONS Cutting Plotting Conditions List...
Page 120: ...CHAPTER 8 SPECIFICATIONS PRODUCT SUMMARY 8 1 Main Specifications 8 2 External Dimensions...
Page 129: ...www delinit by...