Test Modes and Troubleshooting
♦
C6 - 21
ERROR 10 Invalid
I/O output request
ERROR 11 invalid
byte following ESC.
ERROR 12 invalid
byte in I/O control
ERROR 13 Out of
range I/O parameters
ERROR 14 Too many
I/O parameters
ERROR 15 Error in
I/O transmission
ERROR 16 I/O buffer
overflow
Cause
Solution
During the execution of an
output command, another
output command was
executed.
Check the flow of your
programmed data.
Cause
Solution
The ESC character was
followed by an invalid byte.
Check the ESC command
in your program
Cause
Solution
A device control command
containing an invalid byte
was received.
Check the device control
commands in your
program.
Cause
Solution
A parameter outside of the
permissible numeric range
was specified.
Check the program
Cause
Solution
Too many parameters were
received
Check the number of
command parameters
Cause
Solution
During data transfer, a
framing error, parity error or
overrun error occurred.
Check the settings of the
interface conditions
Cause
Solution
The I/O buffer received data
at a faster pace than it could
process, indicating that
handshaking is not
successful
Check the settings of the
handshaking mode and
other interface conditions.
Summary of Contents for Cutting Pro FC4100-100
Page 1: ...cutting pro FC4100 series series USER S MANUAL 1 a...
Page 138: ...Setting the Interface Functions C7 7 Input Output Circuitry Input Output Timing Chart...
Page 147: ...Specifications C8 6 FC4100 100 without Stand FC4100 100 with Stand Standard and Basket Option...
Page 148: ...Specifications C8 7 FC4100 130 without Stand FC4100 130 with Stand Standard and Basket Option...