FC2240-UM-251-9370
8-10
8. ELECTRICAL ADJUSTMENTS
8.8 Clearing the Non-Volatile RAM
NOTE: Be sure to clear the non-volatile RAM after replacing the main board or before starting any electrical
adjustment.
(1) After setting the SW1 DIP switch as shown below, turn on the plotter.
Set bits 2, 3, 5, 6 and 7 to ON
1 2 3 4 5 6 7 8
ON
OFF
(2) The messages below consecutively appear on the LCD panel.
NOVRAM INIT.
0% CLEAR
NOVRAM INIT.
100% CLEAR
(3) After the “
NOVRAM INIT. 100% CLEAR
” message is displayed, a menu for model selection
appears on the LCD panel.
SET FC TYPE
FC2240-60-*2
(4) Select your plotter model using the the
and
keys, and then press the ENTER key to register your
plotter model setting.
FC2240-180-*2
FC2240-120-*2
FC2240-60-*2
(5) The message below appears to select the moving coil type for each pen holder.
SET No.1 MC
MCx1 MAX=40 [500g]
Select MCx1 using the
and
keys for the No.1 pen, and then press the ENTER key to register
your plotter.
(6) The message below appears.
SET No.2 MC
MCx2 MAX=40 [1000g]
Select MCx2 using the
and
keys for the No.2 pen, and then press the ENTER key to register
your plotter.
Summary of Contents for FC2240
Page 1: ...CUTTING MACHINE SERVICE MANUAL FC2240 FC2240 UM 251 04 9370...
Page 2: ......
Page 8: ...FC2240 UM 251 9370 vi...
Page 38: ...FC2240 UM 251 9730 3 15 3 OPERATIONS Sample printout by the CONDITION function...
Page 42: ...FC2240 UM 251 9730 4 2 4 DAILY MAINTENANCE AND STORAGE...
Page 70: ...FC2240 UM 251 9370 7 26 7 DISASSEMBLY AND ADJUSTMENT...