FC2240-UM-251-9370
8-17
8. ELECTRICAL ADJUSTMENTS
(10) Remove the paper and measure the X-axis distance, Y-axis distance and the diagonal distance. If you
have replaced the main board only, use the recorded values.
(11) Input the axis adjustment values using the F1 to F4 keys.
Press the [F1] or [F2] key to change the X-axis adjustment value.
Press the [F3] or [F4] key to change the Y-axis adjustment value.
The formula of the input value is as follows:
Input value for X-axis = (500 mm - measured distance) x 10
Input value for Y-axis = (700 mm - measured distance) x 10
For example:
If you measured 499.7 mm for the X-axis, input 3 for the adjustment value.
Press the [F1] key to select the +0.1-mm step unit.
(12) Press the ENTER key to display the menu shown below.
+0.1 X-Y LENG -0.1
+0.01 L=860.23 -0.01
[F1] key (+0.1)
:Increase the diagonal distance value in 0.1-mm steps.
[F2] key (+0.01)
:Increase the diagonal distance value in 0.01-mm steps.
[F3] key (-0.1)
:Decrease the diagonal distance value in 0.1-mm steps.
[F4] key (-0.01)
:Decrease the diagonal distance value in 0.01-mm steps.
(13) Input the diagonal adjustment values using the [F1] to [F4] keys.
The displayed L value is the diagonal distance.
If the measured value is within the displayed L value of the specification range (±0.1 mm) or if you have
input the recorded value, press the [ENTER] key to store the setting.
(14) The following menu appears.
<ORIGINAL CLEAR>
<ADJ.DRAW INPUT>
(15) If you have changed the diagonal distance value, confirm the axis distance.
Load a new sheet of paper and press the [F2] key to draw the adjusted test pattern.
Measure each distance. If the measured values are within the specification range, press the [ENTER]
key to store the setting.
Specification range for the X distance = 500 mm ±0.2 mm.
Specification range for the Y distance = 700 mm ±0.2 mm.
Specification range for the diagonal distance = within 0.1 mm from the displayed L value.
If the measured value is outside the specification range, adjust again from step (6).
(16) When the adjustment is complete, turn off the power to the plotter.
(17) Return the DIP switch to its default settings (see subsection 8.6 “Setting the DIP Switches”).
Summary of Contents for FC2240
Page 1: ...CUTTING MACHINE SERVICE MANUAL FC2240 FC2240 UM 251 04 9370...
Page 2: ......
Page 8: ...FC2240 UM 251 9370 vi...
Page 38: ...FC2240 UM 251 9730 3 15 3 OPERATIONS Sample printout by the CONDITION function...
Page 42: ...FC2240 UM 251 9730 4 2 4 DAILY MAINTENANCE AND STORAGE...
Page 70: ...FC2240 UM 251 9370 7 26 7 DISASSEMBLY AND ADJUSTMENT...