FC2240-UM-251-9370
8-21
8. ELECTRICAL ADJUSTMENTS
8.16 Testing the Control Panel Keys and Home Sensors
Run this test if a control panel key or home sensor has malfunctioned.
(1) Set the SW1 DIP switch as shown below and then turn on the plotter.
Set all bits to OFF
1 2 3 4 5 6 7 8
ON
OFF
(2) The menu below appears, so press the panel key corresponding to each bit and check that its value
properly changes to the corresponding character or 0.
KEY & SNS TEST MODE
OPCERLUD00TN4321XY
Press each key on the control panel; the status will change as shown below.
Key
Status of LCD
18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
RIGHT ARROW
0 0 0 0 R 0 0 0 0 0 0 0 0 0 0 0 0 0
DOWN ARROW
0 0 0 0 0 0 0 D 0 0 0 0 0 0 0 0 0 0
UP ARROW
0 0 0 0 0 0 U 0 0 0 0 0 0 0 0 0 0 0
LEFT ARROW
0 0 0 0 0 L 0 0 0 0 0 0 0 0 0 0 0 0
F1
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0
F2
0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 0 0 0
F3
0 0 0 0 0 0 0 0 0 0 0 0 0 3 0 0 0 0
F4
0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0
NEXT
0 0 0 0 0 0 0 0 0 0 0 N 0 0 0 0 0 0
TEST
0 0 0 0 0 0 0 0 0 0 T 0 0 0 0 0 0 0
ENTER
0 0 0 E 0 0 0 0 0 0 0 0 0 0 0 0 0 0
CONDITIONS
0 0 C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
COPY
0 P 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
ORIGIN
O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
X home sensor
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 X 0
Y home sensor
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Y
Normal status : 0
Key Test
While the key is pressed : corresponding character
The PAUSE key can be checked by observing its lamp.
Sensor Test
The status of each sensor is displayed on the LCD panel.
KEY & SNS TEST MODE
0000000000000000XY
Display
Sensor name
Operation when the High/Low level changes
2nd bit
X home sensor
When the dog blocks the sensor
X
1st bit
Y home sensor
Same as the above
Y
If a sensor is not operating properly, check its wiring, its connector contact, and the position of the sensor
dog. If everything checks out all right, either the sensor or main board may be defective.
In this case, initialize the NOV-RAM and then run the sensor test again.
As a temporary measure for dealing with a defective sensor, turn off the plotter, set Bit 6 of the DIP
switch to OFF, and then turn the plotter back on.
Summary of Contents for FC2240
Page 1: ...CUTTING MACHINE SERVICE MANUAL FC2240 FC2240 UM 251 04 9370...
Page 2: ......
Page 8: ...FC2240 UM 251 9370 vi...
Page 38: ...FC2240 UM 251 9730 3 15 3 OPERATIONS Sample printout by the CONDITION function...
Page 42: ...FC2240 UM 251 9730 4 2 4 DAILY MAINTENANCE AND STORAGE...
Page 70: ...FC2240 UM 251 9370 7 26 7 DISASSEMBLY AND ADJUSTMENT...