FC7000-UM-251-9370
7-22
7. ADJUSTMENT
(10) Press the F1 key to plot the adjustment pattern shown below.
Plotted target mark
Adjustment lines
(11) The plotter immediately adjusts the registration mark sensor position automatically, and adds a vertical
line and a horizontal line to the scanned plotted pattern.
(12) Measure the offset between the lines and confirm that they are within 0.25 mm.
(13) Turn off the power to exit from the adjustment menu.