FC7000-UM-251-9370
7-28
7. ADJUSTMENT
(12) Measure the gap between the 2nd pen holder and the 2nd pen station.
2nd Pen Holder
2nd Pen Station
Right Side Plate
1 mm
(13) Adjust the gap to a value of 1 mm.
Press the LEFT or RIGHT ARROW key to change the PENSELE POS. value.
(1 unit = 0.05 mm)
(14) Press the ENTER key to store the setting and complete the adjustment.