FC9000-UM-251-9370 8-25
8 Electrical Adjustment
8.13 Adjusting the Distance Accuracy
This adjustment will set the distance and the perpendicularity accuracy.
Perform this procedure if adjustment values could not copy from the SUB-NVRAM when replacing the main
board.
When the main board was replaced, input the recorded adjustment values.
When the drive roller was replaced, adjust the distance accuracy from the measuring distance.
8.13.1 Inputting the distance accuracy from the recorded value
How to input the distance accuracy from the recorded value
(1) Turn on the power while pressing the SLOW and the ENTER keys.
(2) The plotter displays the following menu.
(3) Press the PAUSE/MENU key to display the following menu.
(4) Press the Right Position key to display the adjustment menu shown below.
(5) Press the F3 key to display the following menu.
(6) Press the F2 key to display the following menu.
UP and down allow keys changes value
Slow key changes unit
(7) Input the X-axis distance adjustment value from the recorded value of X.