FC9000-UM-251-9370 8-65
8 Electrical Adjustment
(5)
Run the SerialNumberConfig.exe, the following menu is displayed.
Input serial number here.
(6) Input serial number for the FC9000.
(7) Press the Write button to backup the adjustment values to the Sub-NVRAM.
(8) Turn off the power after the “READY” was displayed on the LCD of FC9000.
(9) Turn on the power while pressing the DOWN ARROW key and the ENTER key.
(10) The following menu will be displayed.
The adjustment values are possible to copy to the new main board if the status of SERIAL NUMBER
and the FACTORY_VALUE are showing the “OK”.
(11)
Confirm that the status of SERIAL NUMBER and the FACTORY_VALUE are showing the “OK”.
And confirm the correct serial number is showing.
(12) Turn off the power for the FC9000.