FC9000-UM-251-9370 27
9 TROUBLESHOOTING
Error
code
Error Display
Cause
Solution
E04020
This error is displayed when
the abnormal registration
marks are detected.
Confirm position of registration mark
and the cutting data.
E04021
This error is displayed when
the 1st registration mark
was not detected in the auto
detection area.
Check the media. Check the print
position of the registration mark.
E04022
There was cancel operation by
the user.
Redo the process.
E04023
Registration mark was not
detected.
Redo the sensor level adjustment.
Change the color of the registration
mark.
Check the media.
Check the print position of the
registration mark.
E04024
Registration mark was not
detected.
Redo the sensor level adjustment.
Change the color of the registration
mark.
Check the media.
Check the print position of the
registration mark.
E04025
E04026
This error is displayed when
the rotation was set to ON with
the segment registration mark
operation.
Set the rotation setting to OFF.
E04027
This error is displayed when
the mirror was set to ON with
the segment registration mark
operation.
Set the mirror setting to OFF.
E04028
Amount of data has exceeded
the ARMS buffer size for the
segment area registration
mark.
Decrease the data.
Summary of Contents for FC9000-100