FC9000-UM-251-9370 40
9 TROUBLESHOOTING
9.7.6 Registration Mark Sensor Test
This test confirms output level of registration mark sensor.
When there is output from the sensor, the registration mark sensor is not defective.
Preparation
Print out the registration mark sensor sensitivity adjustment sheet which is on the last page of chapter 8 to A4
size white copy paper.
LOAD MEDIA TO FC9000 (SHEET)
MOVE TOOL POSITION TO CENTER OF WHITE SQUARE.
REGISTRATION MARK SENSOR LEVEL ADJUST
How to test the registration mark sensor
(1) Turn on the power while pressing the SLOW and the ENTER keys.
(2) The plotter displays the following menu.
(3) Press the PAUSE/MENU key to display the following menu.
(4) Press the Right position key to display the adjustment menu shown below.