FC9000-UM-251-9370 12-10
12 Target electrical component for WEEE instruction
• Removing (D) Switching Power Supply Unit
(1) Remove the four M4L6 binding head screws from the left side cover.
(2) Detach the left side cover.
M4L6 binding head screw
Left side cover
(3) Disconnect all cables from the power supply board.
(4) Remove the four M3L6 binding head screws holding the power supply board, and then detach it.
Power supply board
M3L6 binding head screw
Summary of Contents for FC9000-100
Page 1: ...CUTTING PLOTTER SERVICE MANUAL FC9000 75 100 140 160 FC9000 UM 251 01 9370...
Page 2: ......
Page 4: ...FC9000 UM 251 9370 II...
Page 38: ......
Page 201: ...FC9000 UM 251 9370 10 2 10 PARTS LIST Outer Casing 1 2 3 4 10 7 11 5 16 15 6 12 12 9 13 14 8...