FC9000-UM-251-9370 8-33
8 Electrical Adjustment
8.15 Adjusting the Offset of Registration Mark Sensor
This adjustment will set the offset of tool and the registration mark senor position.
Perform this procedure if adjustment values could not copy from the SUB-NVRAM when replacing the main
board or the registration mark sensor was replaced or detached.
When the main board was replaced, input the offset value from the recorded values.
When the registration mark sensor was replaced, the registration mark sensor sensitivity adjustment must be
performed before this adjustment.
When the registration mark sensor was replaced or detached, this adjustment must be performed.
Preparation
When the registration mark sensor was replaced or removed, print out the target sheet which is on the last
page of this chapter to A4 size white copy paper.
AUTO REGISTRATION MARK TARGET
The specification of the cross mark is 30 mm line length, and 0.3 to 0.5mm line width.
8.15.1 Inputting the registration mark sensor offset position from the
recorded values
How to input the registration mark sensor offset position from the recorded values
(1) Turn on the power while pressing the SLOW and the ENTER keys.
(2) The plotter displays the following menu.
(3) Press the PAUSE/MENU key to display the following menu.
Summary of Contents for FC9000-100