42
8960ENC Instruction Manual
Functional Description
Functional Description
while reading the following func-
tional description.
Figure 23. 8960ENC Block Diagram
Serial 4:2:2 Input Stage & Output
The SDI signal is connected to the high impedance loop-through input. The
input amplifier auto-equalizes the signal up to 24 dB loss (300 meters of
Belden 8281 cable). The reclocked signal is available on two SDI output
connectors and also on an internal 10-bit parallel bus for further pro-
cessing. Error Detection Handling (EDH) is tested by the microcontroller
which flashes the Fault LED when errors are detected.
+12V
Module Slot ID
Fault Reporting
Local User
Interface
Intra-frame Control Interface
4:2:2
SDI
Input
10
10
10
4X NTSC/PAL
2X SDI
Optional Submodule *
Available with Frame
Communication Upgrade
* The main encoder module automatically recognizes the attachment of the frame synchronizer submodule.
NTSC/PAL
Reference
-5V
+5V
Microcontroller
On-board
Switching Mode
Power Supply
module
Serial to
Parallel
Converter
EDH
Frame Delay/
Synchronizer
H Genlock to
External Video
Color Frame
ID Generation
Output
Filter and
Driver
Cross-color
Remover
&
Genlock
with
FIFO
10-bit
Composite
Encoder
0642-01
RC
Summary of Contents for 8960ENC -
Page 4: ...4 8960ENC Instruction Manual Contents Index 49 ...
Page 6: ...6 8960ENC Instruction Manual Preface ...
Page 33: ...8960ENC Instruction Manual 33 Configuration Figure 17 Timing Web Page ...
Page 34: ...34 8960ENC Instruction Manual Configuration Figure 18 Timing Web Page Slider Controls ...
Page 38: ...38 8960ENC Instruction Manual Configuration Figure 21 8960ENC Slot Config Web Page ...