Encore — Configuration Manual
203
Concerto Port Matrix One-to-Many Control
2.
Go to
Config
,
Physical Matrix
, choose the Crosspoint Group being used for
the Concerto Port Router, then click on
Matrix Type
, and choose
Concerto
Port Multi Drop Router
).
Figure 128. Matrix Type for Multi Drop Concerto Port Router
3.
If you are not already using one-to one Concerto Port routing, you will
also need to define the rest of the Port Router configuration parameters
on this menu.
4.
You will also need to go to
Config
,
Source
, and
Config
,
Destination
and define
Sources and Destination of the port routed devices to use connectors on
that Multi Data level. Both the Source and Destination for each device
need to be defined to use the same connector since bi-directional
communications is used for the first controlled device.
Note
If you wish to have device control follow video routing, define these data
S
ources and Destinations as an additional Level for the device’s video
S
ources and Destinations.
5.
Finally, you will need a Control Panel able to do multi destination
routing (an Encore 48B, for example) configured with access to the
various devices’ Sources and Destinations.
Refer to the separate
Concerto Configuration Manual
for more detailed con-
figuration information.
Summary of Contents for Encore
Page 1: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 3: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 14: ...14 Encore Configuration Manual Contents ...
Page 36: ...36 Encore Configuration Manual Section 2 Encore Fundamentals ...
Page 54: ...54 Encore Configuration Manual Section 3 Encore OUI Description ...
Page 284: ...284 Encore Configuration Manual Section 6 Control Panel Configuration PMB Paging MultiBus XY ...
Page 382: ...382 Encore Configuration Manual Section 8 Additional OUI Operations ...
Page 406: ...406 Encore Configuration Manual Section 9 System Manager Reference ...