116
Encore — Configuration Manual
Section 5 — Router Configuration
13.
Click the
Protocol
button and select the desired protocol from the list
window that appears on the screen. The
Data Bits
,
Stop Bits
,
Baud Rate
,
Parity
and
Hand Shake
parameters are automatically set to comply with
the selected protocol. These values should be confirmed with the router
manufacturer’s serial communication guidelines.
Note
Use GVG CPL protocol for Ethernet interface to Grass Valley Group matrices.
14.
If configuring a serial communications channel do the following”
a.
Click the
Port
button to specify a serial port on the Router Controller.
All router matrices using the channel defined in
will
communicate with the Router Controller via this port.
b.
If necessary, change the
Data Bits
,
Stop Bits
,
Baud Rate
,
Parity
or
Hand
Shake
parameters by clicking the relevant buttons and choosing
from the list which appears.
15.
Click the
Initialize Channel
button to finalize all the information
associated with the specified communication channel.
16.
Click the
Save
button to save all of your settings.
17.
If you change an existing I/O Channel configuration, you must now
click the
Re-Sync Comms
button to apply your changes throughout the
network.
To continue with a new configuration, proceed directly to
, or read the intervening explanatory material
first.
Physical Matrix Screen Description
The Physical Matrix Configuration screen (
) is used to define the
configuration parameters of the controlled matrices. Since a communica-
tion channel must be specified before you can control a matrix, the commu-
nication channels should be configured first (see
Summary of Contents for Encore
Page 1: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 3: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 14: ...14 Encore Configuration Manual Contents ...
Page 36: ...36 Encore Configuration Manual Section 2 Encore Fundamentals ...
Page 54: ...54 Encore Configuration Manual Section 3 Encore OUI Description ...
Page 284: ...284 Encore Configuration Manual Section 6 Control Panel Configuration PMB Paging MultiBus XY ...
Page 382: ...382 Encore Configuration Manual Section 8 Additional OUI Operations ...
Page 406: ...406 Encore Configuration Manual Section 9 System Manager Reference ...