Physical Matrix Screen Description
Figure 73. Physical Matrix Configuration Screen
Name
Displays the name of the selected Crosspoint Group. Also
allows a Crosspoint Group to be selected, named, or
renamed. See
for a defini-
tion and explanation of Crosspoint Groups.
No. Inputs
Allows the number of inputs to be defined for a particular
Crosspoint Group.
No. Outputs
Allows the number of outputs to be defined for a partic-
ular Crosspoint Group.
Loop Back
indicator
Indicates whether loop back functionality is enabled.
Once enabled, no information is sent to the matrix. This
allows the simulation of system operation without having
a physical matrix connected. GVG CPL supports this
mode. The Dummy Matrix protocol only supports Loop
Back.
No. Controllers
Allows the number of controllers to be defined for a par-
ticular Crosspoint Group. Limit is 32.
No. Segments
Allows the number of Segments to be defined for a partic-
ular Crosspoint Group. Limit is eight.
Summary of Contents for Encore
Page 1: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 3: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 14: ...14 Encore Configuration Manual Contents ...
Page 36: ...36 Encore Configuration Manual Section 2 Encore Fundamentals ...
Page 54: ...54 Encore Configuration Manual Section 3 Encore OUI Description ...
Page 284: ...284 Encore Configuration Manual Section 6 Control Panel Configuration PMB Paging MultiBus XY ...
Page 382: ...382 Encore Configuration Manual Section 8 Additional OUI Operations ...
Page 406: ...406 Encore Configuration Manual Section 9 System Manager Reference ...