210
Encore — Configuration Manual
Section 6 — Control Panel Configuration
Panel Server Redundancy and IP Addresses
Redundancy parameters (namely the Mode and IP) can be configured after
making the Panel Server offline. Choose the redundancy mode and then
choose the partner’s EN1’s IP address. Make sure the mode and IP
addresses on both partners correctly match.
For example, suppose, SCB1 with IP address 192.168.0.100 is to be config-
ured as master and SCB2 with IP address 192.168.0.101 to be configured as
mirror (slave). On OUI of the Panel Server running on SCB1, choose the
mode as
Mirror Master
and IP as
192.168.0.101
. On OUI of the Panel Server
running on SCB2, choose the mode as
Mirror Slave
and IP as
192.168.0.100
.
Reasons for Loss of Redundancy Sync
With Encore 1.7.3 and newer software, Control Panel Servers can display
the reasons why a redundant pair of CPSs are not in sync. If the mirror and
master CPSs report
No Sync
on the Panel Server screen of the OUI, clicking
on the
Status
text box opens a pop-up window. This window lists the
reason(s) preventing synchronization. Users should check both the Master
and Mirror CPS to get an accurate and comprehensive list of reasons.
If any panels are connected to only the Mirror or Master CPS, the panel
names will be displayed in the popup window. A possible solution to this
situation is to go to the Panel Network web page of each panel and ensure
that the Primary and Secondary server IP addresses are specified correctly.
When a CPS starts up or is placed on-line, and when a control panel signs
on, the CPSs will go out of sync briefly. The CPSs will indicate an approxi-
mate time (in seconds) needed to regain synchronization in the popup
window.
Panel Server Configuration Save and Load
The Panel Server allows multiple configurations to be saved in the Sharer
database and easily reloaded by selecting the desired configuration name
from the list of saved configurations. These Panel Server configurations
Simple
Crosspoint
Logging
Makes the Panel Server application print crosspoint activ-
ities to the console of the SCB. The console can be viewed
serially or via Telnet. The console output can also be cap-
tured to a file using Hyperterminal.
Alpha Sort
When enabled, Alpha Sort will be the default order used
to display Sources and Destinations in their list windows.
When disabled, the display order is by Source and Desti-
nation index number.
Summary of Contents for Encore
Page 1: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 3: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 14: ...14 Encore Configuration Manual Contents ...
Page 36: ...36 Encore Configuration Manual Section 2 Encore Fundamentals ...
Page 54: ...54 Encore Configuration Manual Section 3 Encore OUI Description ...
Page 284: ...284 Encore Configuration Manual Section 6 Control Panel Configuration PMB Paging MultiBus XY ...
Page 382: ...382 Encore Configuration Manual Section 8 Additional OUI Operations ...
Page 406: ...406 Encore Configuration Manual Section 9 System Manager Reference ...